A comparison of anaesthetic tensions in arterial blood and oxygenator exhaust gas during cardiopulmonary bypass

被引:20
作者
Lockwood, GG [1 ]
Sapsed-Byrne, SM [1 ]
Adams, S [1 ]
机构
[1] Hammersmith Hosp, Div Surg Anaesthesia & Intens Care, London W12 0HS, England
关键词
oxygenators; membrane; cardiopulmonary bypass; anaesthetics; inhalation; desflurane; isoflurane monitoring; intra-operative;
D O I
10.1046/j.1365-2044.1999.00847.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study evaluates the usefulness of the analysis of gas sampled from the exhaust port of a membrane oxygenator in the estimation of anaesthetic tension in arterial blood. Sixty-seven arterial blood samples were drawn from patients undergoing hypothermic cardiopulmonary bypass with anaesthesia maintained by either isoflurane or desflurane. Anaesthetic tensions in the oxygenator exhaust gas were measured using an infrared analyser and in arterial blood using a two-stage headspace technique with a gas chromatograph. Both measurement systems were calibrated with the same standard gas mixtures. There was no difference in anaesthetic tension measured in arterial blood and gas leaving the oxygenator exhaust (isoflurane: n = 29, range: 0.3-0.8%, 95% limits of agreement: - 0.08% to 0.09%; desflurane: n = 38, range: 1.5-5.4%; 95% limits of agreement - 0.65% to 0.58%). We conclude that anaesthetic tensions in arterial blood can be accurately monitored by analysis of the gas emerging from the exhaust port of a membrane oxygenator.
引用
收藏
页码:434 / 436
页数:3
相关论文
共 9 条
[1]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[2]   THE OXYGENATOR ARTERIAL SAMPLING PORT - A POTENTIAL SOURCE OF ERROR [J].
GRAVENSTEIN, N ;
ROLLMAN, JE ;
BERRYESSA, RG ;
SLOGOFF, S .
ANESTHESIOLOGY, 1985, 62 (06) :825-826
[3]   In vitro uptake and elimination of isoflurane by different membrane oxygenators [J].
Hickey, S ;
Gaylor, JDS ;
Kenny, GNC .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (03) :352-355
[4]   NOMOGRAMS FOR CORRECTION OF BLOOD PO2, PCO2, PH AND BASE EXCESS FOR TIME AND TEMPERATURE [J].
KELMAN, GR ;
NUNN, JF .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (05) :1484-&
[5]   Effect of temperature on the solubility of desflurane, sevoflurane, enflurane and halothane in blood [J].
Lockwood, GG ;
SapsedByrne, SM ;
Smith, MA .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (04) :517-520
[6]   WASHIN AND WASHOUT OF ISOFLURANE ADMINISTERED VIA BUBBLE OXYGENATORS DURING HYPOTHERMIC CARDIOPULMONARY BYPASS [J].
NUSSMEIER, NA ;
LAMBERT, ML ;
MOSKOWITZ, GJ ;
COHEN, NH ;
WEISKOPF, RB ;
FISHER, DM ;
EGER, EI .
ANESTHESIOLOGY, 1989, 71 (04) :519-525
[7]  
NUSSMEIER NA, 1988, ANESTH ANALG, V67, P982
[8]   A new method for measurement of anaesthetic partial pressure in blood [J].
Smith, MA ;
SapsedByrne, SM ;
Lockwood, GG .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (04) :449-452
[9]  
Zia M, 1992, J Cardiothorac Vasc Anesth, V6, P42, DOI 10.1016/1053-0770(91)90043-S