Parallel ion parking of protein mixtures

被引:43
作者
Chrisman, PA [1 ]
Pitteri, SJ [1 ]
McLuckey, SA [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1021/ac0515778
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The multiple charging phenomenon resulting from electrospray ionization of proteins, while useful for the ability to make several mass measurements on a single component, can lead to highly complex spectra when mixtures are analyzed, as each component can generate multiple ions of distinct mass-to-charge ratio. Ion/ion protontransfer reactions can overcome this problem by reduction of all components to the +1 charge state, but this typically requires the ability to extend the mass range of the instrument well beyond that available in most commercial instruments. Furthermore, reduction of protein charge to +1 also results in a reduction in detector response. Here it is shown that application of a relatively high amplitude, low-frequency auxiliary ac signal to the end cap electrodes of a 3-D ion trap during an ion/ion reaction can slow the ion/ion reaction rates of ions over a broad m/z range, in a process termed HALF parallel ion parking. Adjustment of the frequency and amplitude of the applied voltage allows the mass range into which the initial ion signal is moved to be controlled, allowing for the simplification of multicomponent mixtures within a mass range that is more commonly available on commercial systems. In addition to decreasing spectral complexity, this is advantageous for mixtures with low-abundance components, as there is less compromise with detector response than in reduction to the +1 charge state. Preliminary evidence also suggests that the ion collision cross section may play an important role in determining which charge states are most significantly inhibited from further ion/ion reactions under a given set of ion parking conditions.
引用
收藏
页码:310 / 316
页数:7
相关论文
共 29 条
[1]   Parallel ion parking: Improving conversion of parents to first-generation products in electron transfer dissociation [J].
Chrisman, PA ;
Pitteri, SJ ;
McLuckey, SA .
ANALYTICAL CHEMISTRY, 2005, 77 (10) :3411-3414
[2]   Anion dependence in the partitioning between proton and electron transfer in ion/ion reactions [J].
Coon, JJ ;
Syka, JEP ;
Schwartz, JC ;
Shabanowitz, J ;
Hunt, DF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) :33-42
[3]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[4]   FILTERED NOISE FIELD SIGNALS FOR MASS-SELECTIVE ACCUMULATION OF EXTERNALLY FORMED IONS IN A QUADRUPOLE ION-TRAP [J].
GOERINGER, DE ;
ASANO, KG ;
MCLUCKEY, SA ;
HOEKMAN, D ;
STILLER, SW .
ANALYTICAL CHEMISTRY, 1994, 66 (03) :313-318
[5]  
GROSSHANS, 2004, Patent No. 6674067
[6]  
GROSSHANS PB, 2003, Patent No. 6570151
[7]   Resolution and chemical formula identification of aromatic hydrocarbons and aromatic compounds containing sulfur, nitrogen, or oxygen in petroleum distillates and refinery streams [J].
Guan, SH ;
Marshall, AG ;
Scheppele, SE .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :46-71
[8]   Automated reduction and interpretation of high resolution electrospray mass spectra of large molecules [J].
Horn, DM ;
Zubarev, RA ;
McLafferty, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (04) :320-332
[9]  
Kelley PE, 1992, US Patent, Patent No. 5134286
[10]   A NEW APPROACH FOR THE STUDY OF GAS-PHASE ION-ION REACTIONS USING ELECTROSPRAY IONIZATION [J].
LOO, RRO ;
UDSETH, HR ;
SMITH, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (07) :695-705