The modecleaner system and suspension aspects of GEO 600

被引:20
作者
Gossler, S
Casey, MM
Freise, A
Grote, H
Lück, H
McNamara, P
Plissi, MV
Robertson, DI
Robertson, NA
Skeldon, K
Strain, KA
Torrie, CI
Ward, H
Willke, B
Hough, J
Danzmann, K
机构
[1] Univ Hannover, Inst Atom & Mol Phys, Spekt Abt, D-30169 Hannover, Germany
[2] Max Planck Inst Gravitat Phys, Albert Einstein Inst, Teilinst Hannover, D-30169 Hannover, Germany
[3] Univ Glasgow, Dept Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
关键词
D O I
10.1088/0264-9381/19/7/382
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
GEO 600 uses two 8 m triangular ring cavities as a modecleaner system for the stabilization of the laser. To isolate the cavities with respect to the seismic noise the optical components are suspended as double pendulums. The resonances of these pendulums are damped by a local-control loop via magnet-coil actuators acting on the intermediate masses. The suspension scheme and the measured key data (i.e. finesse, linewidth, visibility, throughput and in-lock durations of the cavities, as well as the isolation performance and the resulting frequency stability) of the modecleaner system will be given in this paper. Furthermore an overview of the GEO 600 interferometer suspension will be given.
引用
收藏
页码:1835 / 1842
页数:8
相关论文
共 11 条
[1]   Silica research in Glasgow [J].
Barr, BW ;
Cagnoli, G ;
Casey, MM ;
Clubley, D ;
Crooks, DRM ;
Danzmann, K ;
Ellife, EJ ;
Gossler, S ;
Grant, A ;
Grote, H ;
Heptonstall, A ;
Hough, J ;
Jennrich, O ;
Lück, H ;
McIntosh, SA ;
Newton, GP ;
Palmer, DA ;
Plissi, MV ;
Robertson, DI ;
Robertson, NA ;
Rowan, S ;
Skeldon, KD ;
Sneddon, P ;
Strain, KA ;
Torrie, CI ;
Ward, H ;
Willems, PA ;
Willke, B ;
Winkler, W .
CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) :1655-1662
[2]  
BROZEK O, 1999, THESIS U HANNOVER
[3]   Performance of a 1200 m long suspended Fabry-Perot cavity [J].
Freise, A ;
Casey, MM ;
Gossler, S ;
Grote, H ;
Heinzel, G ;
Lück, H ;
Robertson, DI ;
Strain, KA ;
Ward, H ;
Willke, B ;
Hough, J ;
Danzmann, K .
CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) :1389-1397
[4]   The automatic alignment system of GEO 600 [J].
Grote, H ;
Heinzel, G ;
Freise, A ;
Gossler, S ;
Willke, B ;
Lück, H ;
Ward, H ;
Casey, M ;
Strain, KA ;
Robertson, D ;
Hough, J ;
Danzmann, K .
CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) :1849-1855
[5]   GEO 600 triple pendulum suspension system:: Seismic isolation and control [J].
Plissi, MV ;
Torrie, CI ;
Husman, ME ;
Robertson, NA ;
Strain, KA ;
Ward, H ;
Lück, H ;
Hough, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (06) :2539-2545
[6]   Mechanical losses associated with the technique of hydroxide-catalysis bonding of fused silica [J].
Rowan, S ;
Twyford, SM ;
Hough, J ;
Gwo, DH ;
Route, R .
PHYSICS LETTERS A, 1998, 246 (06) :471-478
[7]  
RUDIGER A, 1981, OPT ACTA, V28, P641, DOI 10.1080/713820609
[8]   THERMAL NOISE IN MECHANICAL EXPERIMENTS [J].
SAULSON, PR .
PHYSICAL REVIEW D, 1990, 42 (08) :2437-2445
[9]   MEASUREMENTS OF BEAM GEOMETRY FLUCTUATIONS OF TYPICAL ARGON-ION AND ND-YAG LASERS WITH RELEVANCE TO LASER INTERFEROMETER GRAVITATIONAL-WAVE DETECTORS [J].
SKELDON, K ;
HOUGH, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (04) :2760-2762
[10]   The GEO 600 gravitational wave detector [J].
Willke, B ;
Aufmuth, P ;
Aulbert, C ;
Babak, S ;
Balasubramanian, R ;
Barr, BW ;
Berukoff, S ;
Bose, S ;
Cagnoli, G ;
Casey, MM ;
Churches, D ;
Clubley, D ;
Colacino, CN ;
Crooks, DRM ;
Cutler, C ;
Danzmann, K ;
Davies, R ;
Dupuis, R ;
Elliffe, E ;
Fallnich, C ;
Freise, A ;
Gossler, S ;
Grant, A ;
Grote, H ;
Heinzel, G ;
Heptonstall, A ;
Heurs, M ;
Hewitson, M ;
Hough, J ;
Jennrich, O ;
Kawabe, K ;
Kötter, K ;
Leonhardt, V ;
Lück, H ;
Malec, M ;
McNamara, PW ;
McIntosh, SA ;
Mossavi, K ;
Mohanty, S ;
Mukherjee, S ;
Nagano, S ;
Newton, GP ;
Owen, BJ ;
Palmer, D ;
Papa, MA ;
Plissi, MV ;
Quetschke, V ;
Robertson, DI ;
Robertson, NA ;
Rowan, S .
CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) :1377-1387