Tissue molecular ion imaging by gold cluster ion bombardment

被引:228
作者
Touboul, D
Halgand, F
Brunelle, A
Kersting, R
Tallarek, E
Hagenhoff, B
Laprévote, O
机构
[1] CNRS, Inst Chim Subst Nat, F-91198 Gif Sur Yvette, France
[2] Tascon GmbH, D-48149 Munster, Germany
关键词
D O I
10.1021/ac035243z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of gold cluster focused ion beams produced by a liquid metal ion gun in a TOF-SIMS mass spectrometer is shown to dramatically enhance secondary ion emission of phospholipids and peptides. The method has been successfully tested with cells grown onto plastic slips and with mouse brain slices, without any treatment of the samples. Very reliable time-of-flight mass spectra are acquired with a low primary ion dose of a few 107 ions, and high lateral resolution molecular ion images are obtained for heavy ions of great biological interest. This approach offers new opportunities in pharmacological and biological research fields by localizing compounds of interest such as drugs or metabolites in tissues.
引用
收藏
页码:1550 / 1559
页数:10
相关论文
共 51 条
[41]   CONTRIBUTION OF FIELD EFFECTS TO ACHIEVEMENT OF HIGHER BRIGHTNESS ION SOURCES [J].
SUDRAUD, P ;
VANDEWALLE, J ;
COLLIEX, C ;
CASTAING, R .
SURFACE SCIENCE, 1978, 70 (01) :392-402
[42]   Effect of water treatment on analyte and matrix ion yields in matrix-assisted time-of-flight secondary ion mass spectrometry: the case of insulin in and on hydroxycinnamic acid [J].
Szymczak, W ;
Wittmaack, K .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (21) :2025-2033
[43]   EVIDENCE FOR STRONGLY ENHANCED YIELDS OF NEGATIVE MOLECULAR SECONDARY IONS DUE TO BOMBARDMENT WITH SF(N) CLUSTER IONS [J].
SZYMCZAK, W ;
WITTMAACK, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 88 (1-2) :149-153
[44]   Organic ion imaging of biological tissue with secondary ion mass spectrometry and matrix-assisted laser desorption/ionization [J].
Todd, PJ ;
Schaaff, TG ;
Chaurand, P ;
Caprioli, RM .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (04) :355-369
[45]  
TONKINSON JL, 2002, FRONT BIOSCI, V7, P1
[46]   A C60 primary ion beam system for time of flight secondary ion mass spectrometry:: Its development and secondary ion yield characteristics [J].
Weibel, D ;
Wong, S ;
Lockyer, N ;
Blenkinsopp, P ;
Hill, R ;
Vickerman, JC .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1754-1764
[47]   Secondary ion and electron yield measurements for surfaces bombarded with large molecular ions [J].
Westmacott, G ;
Ens, W ;
Standing, KG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 108 (03) :282-289
[48]   Recent advances in brain cholesterol dynamics: Transport, domains, and Alzheimer's disease [J].
Wood, WG ;
Schroeder, F ;
Avdulov, NA ;
Chochina, SV ;
Igbavboa, U .
LIPIDS, 1999, 34 (03) :225-234
[49]   Matrix-enhanced secondary ion mass spectrometry: A method for molecular analysis of solid surfaces [J].
Wu, KJ ;
Odom, RW .
ANALYTICAL CHEMISTRY, 1996, 68 (05) :873-882
[50]  
ZIEGLER JF, 1985, SRIM 2000 40 STOPPIN