Highly robust stainless steel tips as micro electro spray emitters

被引:33
作者
Ishihama, Y
Katayama, H
Asakawa, N
Oda, Y
机构
[1] Eisai & Co Ltd, Analyt Res Labs, Tsukuba, Ibaraki 3002635, Japan
[2] Eisai & Co Ltd, Lab Seeds Finding Technol, Tsukuba, Ibaraki 3002635, Japan
关键词
D O I
10.1002/rcm.647
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Tapered stainless steel spray tips for sheathless microelectrospray ionization (muESI) have been developed. The fabrication procedure for the tapered stainless steel tips was optimized using an electropolishing technique followed by removal of the burr. Using the tip as the muESI emitter, a stable ESI spray was obtained at a flow rate of 20 nL/min. The sensitivity of the muESI system was almost two orders greater than that of the conventional ion spray system. The tip was highly stable, and was successfully used for over 1000 h. Moreover, these stainless steel tips were suitable for use with sheathless capillary electrophoresis/mass spectrometry (CE/MS) and capillary liquid chromatography/mass spectrometry (LC/MS) for routine analysis in proteomic and pharmaceutical applications. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:913 / 918
页数:6
相关论文
共 18 条
[1]  
Alexander JN, 1998, RAPID COMMUN MASS SP, V12, P1187, DOI 10.1002/(SICI)1097-0231(19980915)12:17<1187::AID-RCM300>3.0.CO
[2]  
2-T
[3]   A design for low-flow sheathless electrospray emitters [J].
Barnidge, DR ;
Nilsson, S ;
Markides, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4115-4118
[4]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[5]   Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused silica capillary [J].
Chang, YZ ;
Her, GR .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :626-630
[6]   METHOD FOR THE ELECTROSPRAY IONIZATION OF HIGHLY CONDUCTIVE AQUEOUS-SOLUTIONS [J].
CHOWDHURY, SK ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1660-1664
[7]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[8]   Identification of proteins by capillary electrophoresis tandem mass spectrometry - Evaluation of an on-line solid-phase extraction device [J].
Figeys, D ;
Ducret, A ;
Aebersold, R .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :295-306
[9]   Surfactants usable for electrospray ionization mass spectrometry [J].
Ishihama, Y ;
Katayama, H ;
Asakawa, N .
ANALYTICAL BIOCHEMISTRY, 2000, 287 (01) :45-54
[10]  
Katayama H, 2000, RAPID COMMUN MASS SP, V14, P1167, DOI 10.1002/1097-0231(20000730)14:14<1167::AID-RCM5>3.0.CO