MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS

被引:431
作者
EMMETT, MR
CAPRIOLI, RM
机构
[1] UNIV TEXAS,SCH MED,CTR ANALYT CHEM,POB 20708,HOUSTON,TX 77225
[2] UNIV TEXAS,SCH MED,DEPT BIOCHEM & MOLEC BIOL,HOUSTON,TX 77225
基金
美国国家卫生研究院;
关键词
D O I
10.1016/1044-0305(94)85001-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A ''micro-electrospray'' ionization source has been developed that markedly increases the sensitivity of the conventional electrospray source. This was achieved by optimization of the source to accommodate nanoliter flow rates from 300 to 800-nL/min spraying directly from a capillary needle that, for the analysis of peptides, contained C18 liquid chromatography packing as an integrated concentration-desalting device. Thus, a total of 1 fmol of methionine enkephalin was desorbed from the capillary column spray needle, loaded as a 10-muL injection of 100-amol/muL solution. The mass spectrum showed the [M + H]+ ion at m/z 574.2 with a signal-to-noise ratio of better than 5:1 from a chromatographic peak with a width of about 12 s. A narrow range (15-u) tandem mass spectrum was obtained for methionine enkephalin from the injection of 500 amol, and a full-scan tandem-mass spectrum was obtained from 50 fmol. For proteins, the average mass measurement accuracy was approximately 100-200 ppm for the injection of 2.5 fmol of apomyoglobin and 20-40 ppm for 200 fmol. Carbonic anhydrase B and bovine serum albumin showed similar mass measurement accuracies.
引用
收藏
页码:605 / 613
页数:9
相关论文
共 20 条
[1]   ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY FOR THE DETECTION OF DISCRETE PEPTIDE METAL-ION COMPLEXES INVOLVING MULTIPLE CYSTEINE (SULFUR) LIGANDS [J].
ALLEN, MH ;
HUTCHENS, TW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (04) :308-312
[2]   DESIGN AND PERFORMANCE OF A NOVEL ELECTROSPRAY INTERFACE [J].
ALLEN, MH ;
VESTAL, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (01) :18-26
[3]  
AUSTELL TL, 1993, 5TH ANN HPCE M ORL
[4]  
AUSTELL TL, 1994, 6TH ANN HPCE M SAN D
[5]   ELECTROSPRAY MASS-SPECTROMETRY FOR THE ANALYSIS OF OPIOID-PEPTIDES AND FOR THE QUANTIFICATION OF ENDOGENOUS METHIONINE ENKEPHALIN AND BETA-ENDORPHIN [J].
DASS, C ;
KUSMIERZ, JJ ;
DESIDERIO, DM ;
JARVIS, SA ;
GREEN, BN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (02) :149-156
[6]   QUANTITATIVE ANALYTICAL MASS-SPECTROMETRY OF ENDOGENOUS NEUROPEPTIDES IN HUMAN PITUITARIES [J].
DESIDERIO, DM .
LIFE SCIENCES, 1992, 51 (03) :169-176
[7]  
EMMETT MR, 1993, 41ST P ASMS C MASS S
[8]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[9]   SMALL-VOLUME AND LOW FLOW-RATE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF AQUEOUS SAMPLES [J].
GALE, DC ;
SMITH, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) :1017-1021
[10]   Characterization of peptides bound to the class I MHC molecule HLA-A2.1 by mass spectrometry (Reprinted from Science, vol 255, March 6, 1992) [J].
Hunt, Donald F. ;
Henderson, Robert A. ;
Shabanowitz, Jeffrey ;
Sakaguchi, Kazuyasu ;
Michel, Hanspeter ;
Sevilir, Noelle ;
Cox, Andrea L. ;
Appella, Ettore ;
Engelhard, Victor H. .
JOURNAL OF IMMUNOLOGY, 2007, 179 (05) :2669-2671