Application of amperometric sol-gel biosensor to flow injection determination of glucose

被引:27
作者
Couto, CMCM
Araújo, AN
Montenegro, MCBSM
Rohwedder, J
Raimundo, I
Pasquini, C
机构
[1] CEQUP, Dept Quim Fis, Fac Farm, P-4050 Oporto, Portugal
[2] Univ Estadual Campinas, Inst Quim, Campinas, SP, Brazil
[3] Inst Super Ciencias Saude, P-4580 Gandra, Paredes, Portugal
关键词
flow injection analysis; glucose oxidase; sol-gel; glucose biosensor;
D O I
10.1016/S0039-9140(01)00587-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose biosensor with enzyme immobilised by sol-gel technology was constructed and evaluated. The glucose biosensor reported is based on encapsulated GOX within a sol-gel glass, prepared with 3-aminopropyltriethoxy silane, 2-(3,4-epoxycyclohexyl)-ethyltrimetoxy silane and HCl. A flow system incorporating the amperometric biosensor constructed was developed for the determination of glucose in the 1 x 10(-4)-5 x 10(-3) mol 1(-1) range with a precision of 1.5%. The results obtained for the analysis of electrolytic solution for iv administration and human serum samples showed good agreement between the proposed method and the reference procedure, with relative error < 5%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:997 / 1003
页数:7
相关论文
共 24 条
  • [11] Pandey PC, 1999, ELECTROANAL, V11, P1251, DOI 10.1002/(SICI)1521-4109(199911)11:17<1251::AID-ELAN1251>3.0.CO
  • [12] 2-M
  • [13] Pandey PC, 1999, ELECTROANAL, V11, P59, DOI 10.1002/(SICI)1521-4109(199901)11:1<59::AID-ELAN59>3.0.CO
  • [14] 2-P
  • [15] A new glucose sensor based on encapsulated glucose oxidase within organically modified sol-gel glass
    Pandey, PC
    Upadhyay, S
    Pathak, HC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 60 (2-3) : 83 - 89
  • [16] SOL-GEL DERIVED RENEWABLE-SURFACE BIOSENSORS
    PANKRATOV, I
    LEV, O
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 393 (1-2) : 35 - 41
  • [17] QU Y, 1995, FOOD CHEM, V2, P187
  • [18] Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer
    Sampath, S
    Lev, O
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2015 - 2021
  • [19] ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers
    Sohn, BK
    Cho, BW
    Kim, CS
    Kwon, DH
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) : 7 - 11
  • [20] Enzyme-epoxy membrane based glucose analyzing system and medical applications
    Sriyudthsak, M
    Cholapranee, T
    Sawadsaringkarn, M
    Yupongchaey, N
    Jaiwang, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (08) : 735 - 742