Zernike-type X-ray imaging microscopy at 25 keV with Fresnel zone plate optics

被引:18
作者
Awaji, M
Suzuki, Y
Takeuchi, A
Takano, H
Kamijo, N
Tamura, S
Yasumoto, M
机构
[1] JASRI, SPring 8, Mikazuki, Hyogo 6795198, Japan
[2] Kansai Med Univ, Osaka 5731136, Japan
[3] Natl Inst Adv Ind Sci & Technol, Osaka 5638577, Japan
[4] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
关键词
Zernike-type imaging microscopy; sputtered-sliced Fresnel zone plates; phase plates; diffusers; partial coherent illumination;
D O I
10.1107/S0909049502004223
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Zernike-type imaging microscope using a sputtered-sliced Fresnel zone plate (SS-FZP) has been developed and tested at an X-ray energy of 25 keV. The SS-FZP was used as an objective. A copper (Cu) phase plate was placed at the back focal plane of the SS-FZP in order to produce phase contrast. The performance of the Zernike-type imaging microscope was tested with a gold (Au) mesh and a resolution test pattern at undulator beamline 47 of SPring-8. The Au mesh and the resolution test pattern could be imaged in transmission with a magnification of x10.2. Owing to the Cu phase plate, different image contrast was observed compared with the bright-field image contrast. Tantalum microstructures down to 0.5 mum line-and-space have been observed on spatial resolution test patterns.
引用
收藏
页码:125 / 127
页数:3
相关论文
共 11 条
[1]  
Awaji M, 2000, AIP CONF PROC, V507, P545, DOI 10.1063/1.1291208
[2]   X-ray imaging microscopy at 25 keV with Fresnel zone plate optics [J].
Awaji, M ;
Suzuki, Y ;
Takeuchi, A ;
Takano, H ;
Kamijo, N ;
Tamura, S ;
Yasumoto, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :845-848
[3]   AN X-RAY INTERFEROMETER [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 6 (08) :155-&
[4]   Present status of SPring-8 insertion devices [J].
Kitamura, H .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :184-188
[5]   Phase-contrast X-ray computed tomography for observing biological soft tissues [J].
Momose, A ;
Takeda, T ;
Itai, Y ;
Hirano, K .
NATURE MEDICINE, 1996, 2 (04) :473-475
[6]  
RUDOLPH D, 1981, SPIE P, V316, P103
[7]   PHASE-CONTRAST STUDIES OF BIOLOGICAL SPECIMENS WITH THE X-RAY MICROSCOPE AT BESSY [J].
SCHMAHL, G ;
RUDOLPH, D ;
GUTTMANN, P ;
SCHNEIDER, G ;
THIEME, J ;
NIEMANN, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1282-1286
[8]  
Tamura S, 1997, MATER RES SOC SYMP P, V441, P779
[9]  
Watanabe N, 2000, AIP CONF PROC, V507, P84, DOI 10.1063/1.1291123
[10]   MODIFICATION OF THE COHERENCE OF UNDULATOR RADIATION [J].
WHITE, DL ;
WOOD, OR ;
BJORKHOLM, JE ;
SPECTOR, S ;
MACDOWELL, AA ;
LAFONTAINE, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1930-1933