Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone

被引:78
作者
Boger, Andreas [1 ]
Bisig, Adrian [1 ]
Bohner, Marc [2 ]
Heini, Paul [3 ]
Schneider, Erich [1 ]
机构
[1] AO Res Inst, CH-7270 Davos, Switzerland
[2] Dr HC Robert Mathys Fdn, CH-2544 Bettlach, Switzerland
[3] Univ Bern, Inselspital, CH-3010 Bern, Switzerland
关键词
Bone cement; vertebroplasty; osteoporosis; poly(methyl metacrylate); porosity;
D O I
10.1163/156856208785540154
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Poly(methyl methacrylate) (PMMA) is by far the most frequently used bone substitute material for vertebroplasty. However, there are serious complications, such as cement leakage and an increased fracture rate of the adjacent vertebral bodies. The latter may be related to the mechanical properties of the augmented segment within the osteoporotic spine. A possible counter-measure is prophylactic augmentation at additional levels, but this aggravates the risk for the patient. Introduction of pores is a possible method to reduce the inherent high stiffness of PMMA. This study investigates the effect of porosity on the mechanical properties of PMMA bone cement. Different fractions of a highly viscous liquid were mixed into the PMMA during preparation. An open-porous material with adjustable mechanical properties resulted after removal of the aqueous phase. Different radiopacifiers were admixed to investigate their suitability for vertebroplasty. The final material was characterized mechanically by compressive testing, microscopically and radiologically. In addition, the monomer release subsequent to hardening was measured by means of gas chromatography. The Young's modulus in compression could be varied between 2800 +/- 70 MPa and 120 +/- 150 MPa, and the compression ultimate strength between 170 +/- 5 MPa and 8 +/- 9 MPa for aqueous fractions ranging between 0 and 50% of volume. Only a slight decrease of the Young's modulus and small changes of ultimate strength were found when the mixing time was increased. An organic hydrophilic and lipophilic radiopacifier led to a higher Young's modulus of the porous material; however, the ultimate strength was not significantly affected by adding different radiopacifiers to the porous cement. The radiopacity was lost after washing the aqueous phase out of the pores. No separation occurred between the aqueous and the PMMA phase during injection into an open porous ceramic material. The monomer released was found to increase for increasing aqueous fractions, but remained comparable in magnitude to standard PMMA. This study demonstrates that a conventional PMMA can be modified to obtain a range of mechanical properties, including those of osteoporotic bone.
引用
收藏
页码:1125 / 1142
页数:18
相关论文
共 30 条
[1]
Abe H, 1996, DATA BOOK MECH PROPE
[2]
Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[3]
Berlemann U, 2002, UNFALLCHIRURG, V105, P2, DOI 10.1007/s113-002-8157-8
[4]
Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure [J].
Bohner, M ;
Gasser, B ;
Baroud, G ;
Heini, P .
BIOMATERIALS, 2003, 24 (16) :2721-2730
[5]
STUDIES ON CHRONIC ORAL TOXICITY OF MONOMERIC ETHYL ACRYLATE + METHYL METHACRYLATE [J].
BORZELLECA, JF ;
CRAWFORD, EM ;
SMITH, RB ;
LARSON, PS ;
HUF, EG ;
HENNIGAR, GR .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1964, 6 (01) :29-&
[6]
Deramond H, 1991, NEURORADIOLOGY S, V33, P177
[7]
POLY(METHYL METHACRYLATE)-AQUEOUS PHASE BLENDS - INSITU CURING POROUS MATERIALS [J].
DEWIJN, JR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (04) :625-635
[8]
GALIBERT P, 1987, NEUROCHIRURGIE, V33, P166
[9]
Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty [J].
Grados, F ;
Depriester, C ;
Cayrolle, G ;
Hardy, N ;
Deramond, H ;
Fardellone, P .
RHEUMATOLOGY, 2000, 39 (12) :1410-1414
[10]
Augmentation of mechanical properties in osteoporotic vertebral bones - a biomechanical investigation of vertebroplasty efficacy with different bone cements [J].
Heini, PF ;
Berlemann, U ;
Kaufmann, M ;
Lippuner, K ;
Fankhauser, C ;
van Landuyt, P .
EUROPEAN SPINE JOURNAL, 2001, 10 (02) :164-171