Adjacent vertebral failure after vertebroplasty - A biomechanical investigation

被引:373
作者
Berlemann, U
Ferguson, SJ
Nolte, LP
Hein, PF
机构
[1] Univ Bern, ME Muller Inst Biomech, CH-3010 Bern, Switzerland
[2] Inselspital Bern, CH-3010 Bern, Switzerland
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2002年 / 84B卷 / 05期
关键词
D O I
10.1302/0301-620X.84B5.11841
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Vertebroplasty, which is the percutaneous injection V of bone cement into vertebral bodies has recently been used to treat painful osteoporotic compression fractures. Early clinical results have been encouraging, but very little is known about the consequences of augmentation with cement for the adjacent, non-augmented level. We therefore measured the overall failure, strength and structural stiffness of paired osteoporotic two-vertebra functional spine units (FSUs). One FSU of each pair was augmented with polymethylmethacrylate bone cement in the caudal vertebra, while the other served as an untreated control. Compared with the controls, the ultimate failure load for FSUs treated by injection of cement was lower. The geometric mean treated/untreated ratio of failure load was 0.81, with 95% confidence limits from 0.70 to 0.92, (p < 0.01). There was no significant difference in overall FSU stiffness. For treated FSUs, there was a trend towards lower failure loads with 2 increased filling with cement (r(2) = 0.262, p = 0.13). The current practice of maximum filling with cement to restore the stiffness and strength of a vertebral body may provoke fractures in adjacent, non-augmented vertebrae. Further investigation is required to determine an optimal protocol for augmentation.
引用
收藏
页码:748 / 752
页数:5
相关论文
共 14 条
[1]
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures [J].
Bai, B ;
Jazrawi, LM ;
Kummer, FJ ;
Spivak, JM .
SPINE, 1999, 24 (15) :1521-1526
[2]
Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[3]
Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[4]
BERLEMANN U, 2000, P ISSLS 26 ANN M AD
[5]
Chiras J, 1997, J NEURORADIOLOGY, V24, P45
[6]
Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up [J].
Cotten, A ;
Dewatre, F ;
Cortet, B ;
Assaker, R ;
Leblond, D ;
Duquesnoy, B ;
Chastanet, P ;
Clarisse, J .
RADIOLOGY, 1996, 200 (02) :525-530
[7]
Vertebroplasty: An opportunity to do something really good for patients [J].
Einhorn, TA .
SPINE, 2000, 25 (09) :1051-1052
[8]
GALIBERT P, 1987, NEUROCHIRURGIE, V33, P166
[9]
CONFIDENCE-INTERVALS RATHER THAN P-VALUES - ESTIMATION RATHER THAN HYPOTHESIS-TESTING [J].
GARDNER, MJ ;
ALTMAN, DG .
BMJ-BRITISH MEDICAL JOURNAL, 1986, 292 (6522) :746-750
[10]
Percutaneous transpedicular vertebroplasty with PMMA:: operative technique and early results -: A prospective study for the treatment of osteoporotic compression fractures [J].
Heini, PF ;
Wälchli, B ;
Berlemann, U .
EUROPEAN SPINE JOURNAL, 2000, 9 (05) :445-450