Biomechanical evaluation of a new bone cement for use in vertebroplasty

被引:272
作者
Belkoff, SM
Mathis, JM
Erbe, EM
Fenton, DC
机构
[1] Univ Maryland, Dept Surg, Div Orthopaed, Orthopaed Biomech Lab, Baltimore, MD 21201 USA
[2] Johns Hopkins Univ, Dept Neuroradiol, Baltimore, MD USA
[3] Orthovita Inc, Malvern, PA USA
关键词
vertebroplasty; bone cement; biomechanics; osteoporosis; spine; vertebral body compression fracture;
D O I
10.1097/00007632-200005010-00004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Comparative ex vivo biomechanical study. Objectives, To determine the strength and stiffness of osteoporotic vertebral bodies subjected to compression fractures and subsequently stabilized via bipedicular injection of one of two bone cements: one is a commercially available polymethylmethacrylate (Simplex P) and one is a proprietary glass-ceramic-reinforced BisGMA/BisEMA/ TEGDWIA matrix composite that is being developed for use in vertebroplasty (Orthocomp), Summary of Background Data. Osteoporotic compression fractures present diagnostic and therapeutic challenges for the clinician. Vertebroplasty, a new technique for treating such fractures, stabilizes vertebral bodies by injection of cement. Little is known, however, about the biomechanics of this treatment. Methods. Five vertebral bodies (L1-L5) from each of four fresh spines were harvested from female cadavers (age, 80 +/- 5 years), screened for bone density using DEXA (t = -3.4 to -6.4), disarticulated, and compressed in a materials testing machine to determine initial strength and stiffness. The fractures then were repaired using a transpedicular injection of either Orthocomp or Simplex P and recrushed, Results. For both cement treatments, vertebral body strength after injection of cement was significantly greater than initial strength values. Vertebral bodies augmented with Orthocomp recovered their initial stiffness; however, vertebral bodies augmented with Simplex P were significantly less stiff than they were in their initial condition. Conclusions. Augmentation with Orthocomp results in similar or greater mechanical properties compared with Simplex P, but these biomechanical results have yet to be substantiated in clinical studies.
引用
收藏
页码:1061 / 1064
页数:4
相关论文
共 25 条
[1]  
[Anonymous], BASIC ORTHOPAEDIC BI
[2]   An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty [J].
Belkoff, SM ;
Maroney, M ;
Fenton, DC ;
Mathis, JM .
BONE, 1999, 25 (02) :23S-26S
[3]  
BOSTROM MP, 1997, SPINE, V22, pS39
[4]   Percutaneous vertebroplasty: State of the art [J].
Cotten, A ;
Boutry, N ;
Cortet, B ;
Assaker, R ;
Demondion, X ;
Leblond, D ;
Chastanet, P ;
Duquesnoy, B ;
Deramond, H .
RADIOGRAPHICS, 1998, 18 (02) :311-320
[5]   Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up [J].
Cotten, A ;
Dewatre, F ;
Cortet, B ;
Assaker, R ;
Leblond, D ;
Duquesnoy, B ;
Chastanet, P ;
Clarisse, J .
RADIOLOGY, 1996, 200 (02) :525-530
[6]   TOXIC EFFECTS OF METHYLMETHACRYLATE MONOMER ON LEUKOCYTES AND ENDOTHELIAL-CELLS IN-VITRO [J].
DAHL, OE ;
GARVIK, LJ ;
LYBERG, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :147-153
[7]  
DALLAP BL, 1999, T ORTHOP RES SOC, V24, P503
[8]  
Debussche-Depriester C., 1991, NEURORADIOLOGY, V33, P149
[9]   Temperature elevation caused by bone cement polymerization during vertebroplasty [J].
Deramond, H ;
Wright, NT ;
Belkoff, SM .
BONE, 1999, 25 (02) :17S-21S
[10]  
Deramond H., 1997, Semin Musculoskelet Radiol, V1, P285, DOI 10.1055/s-2008-1080150