Electrochemical characteristics of glucose oxidase immobilized in poly(quinone) redox polymers

被引:14
作者
Arai, G [1 ]
Shoji, K [1 ]
Yasumori, I [1 ]
机构
[1] Kanagawa Univ, Dept Appl Chem, Kanagawa Ku, Yokohama, Kanagawa 221, Japan
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2006年 / 591卷 / 01期
关键词
poly(quinone); glucose oxidase; glucose sensor;
D O I
10.1016/j.jelechem.2005.02.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose oxidase was immobilized in two redox conductive polymers, poly(methylmereapto-p-benzoquinone) and poly(dimethylmereapto-p-benzoquinone) films, on Au-electroplated glassy carbon electrodes. The two films were prepared by electropolymerization of methylmercapto-hydroquinone and dimethylmereaptohydroquinone, respectively. The resulting enzyme electrodes functioned as direct response type of glucose sensors and could reject the interference of physiological level of electroactive interferents like ascorbic acid and uric acid. The sensors showed excellent selectivity and possessed good durability. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 34 条
[1]  
ALCOLAY W, 1947, HELV CHIM ACTA, V30, P578
[2]  
AMINE A, 1989, ANAL LETT, V22, P2403
[3]   Electrochemical characteristics of D-amino acid oxidase Immobilized in a conductive redox polymer [J].
Arai, G ;
Noma, T ;
Hayashi, M ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 452 (01) :43-48
[4]   ELECTROCHEMICAL STUDIES OF POLY(MERCAPTOHYDROQUINONE) AND POLY(MERCAPTO-PARA-BENZOQUINONE) FILMS PREPARED BY ELECTROPOLYMERIZATION .1. PREPARATION OF PH MICROSENSOR AND ITS FUNDAMENTAL CHARACTERISTICS [J].
ARAI, G ;
KOIKE, T ;
YASUMORI, I .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (02) :806-808
[5]   Pyruvate sensor based on pyruvate oxidase immobilized in a poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Noma, T ;
Habu, H ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 464 (02) :143-148
[6]   Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Takahashi, S ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02) :173-179
[7]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[8]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[9]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[10]   ONLINE MEASUREMENT OF BRAIN GLUTAMATE WITH AN ENZYME/POLYMER-COATED TUBULAR ELECTRODE [J].
BERNERS, MOM ;
BOUTELLE, MG ;
FILLENZ, M .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2017-2021