Single-pipetting microfluidic assay device for rapid detection of Salmonella from poultry package

被引:47
作者
Fronczek, Christopher F. [1 ]
You, David J. [2 ]
Yoon, Jeong-Yeol [1 ,2 ]
机构
[1] Univ Arizona, Biomed Engn Grad Interdisciplinary Program, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
关键词
Salmonella typhimurium; Lab on a chip; Microfluidic device; Latex agglutination test; Immunoagglutination; Mie scatter; Chicken carcass; LATEX IMMUNOAGGLUTINATION ASSAY; LIGHT-SCATTERING; IMMUNOASSAY; PATHOGENS; SAMPLES;
D O I
10.1016/j.bios.2012.07.076
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A direct, sensitive, near-real-time, handheld optical immunoassay device was developed to detect Salmonella typhimurium in the naturally occurring liquid from fresh poultry packages (hereafter "chicken matrix"), with just single pipetting of sample (i.e., no filtration, culturing and/or isolation, thus reducing the assay time and the error associated with them). Carboxylated, polystyrene microparticles were covalently conjugated with anti-Salmonella, and the immunoagglutination due to the presence of Salmonella was detected by reading the Mie scatter signals from the microfluidic channels using a handheld device. The presence of chicken matrix did not affect the light scatter signal, since the optical parameters (particle size d, wavelength of incident light lambda and scatter angle theta) were optimized to minimize the effect of sample matrix (animal tissues and blood proteins, etc.). The sample was loaded into a microfluidic chip that was split into two channels, one pre-loaded with vacuum-dried, antibody-conjugated particles and the other with vacuum-dried, bovine serum albumin-conjugated particles. This eliminated the need for a separate negative control, effectively minimizing chip-to-chip and sample-to-sample variations. Particles and the sample were diffused in-channel through chemical agitation by Tween 80, also vacuum-dried within the microchannels. Sequential mixing of the sample to the reagents under a strict laminar flow condition synergistically improved the reproducibility and linearity of the assay. In addition, dried particles were shown to successfully detect lower Salmonella concentrations for up to 8 weeks. The handheld device contains simplified circuitry eliminating unnecessary adjustment stages, providing a stable signal, thus maximizing sensitivity. Total assay time was 10 min, and the detection limit 10 CFU mL(-1) was observed in all matrices, demonstrating the suitability of this device for field assays. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2008, 204 BANGS LAB
[2]   Effects of various fat sources, α-tocopheryl acetate, and ascorbic acid supplements on fatty acid composition and α-tocopherol content in raw and vacuum-packed, cooked dark chicken meat [J].
Bou, R. ;
Grimpa, S. ;
Guardiola, F. ;
Barroeta, A. C. ;
Codony, R. .
POULTRY SCIENCE, 2006, 85 (08) :1472-1481
[3]  
Centers for Disease Control Division of Bacterial and Mycotic Diseases, 2011, CDC EST FOODB ILLN U
[4]   Rapid detection of pathogens using antibody-coated microbeads with bioluminescence in microfluidic chips [J].
Guan, Xiao ;
Zhang, Hui-jing ;
Bi, Yin-nan ;
Zhang, Li ;
Hao, Dun-ling .
BIOMEDICAL MICRODEVICES, 2010, 12 (04) :683-691
[5]   Single cell level detection of Escherichia coli in microfluidic device [J].
Han, Jin-Hee ;
Heinze, Brian C. ;
Yoon, Jeong-Yeol .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (08) :1303-1306
[6]   The enhanced diffusional mixing for latex immunoagglutination assay in a microfluidic device [J].
Han, Jin-Hee ;
Kim, Kye-Seong ;
Yoon, Jeong-Yeol .
ANALYTICA CHIMICA ACTA, 2007, 584 (02) :252-259
[7]   Nanoparticle immunoagglutination Rayleigh scatter assay to complement microparticle immunoagglutination Mie scatter assay in a microfluidic device [J].
Heinze, Brian C. ;
Yoon, Jeong-Yeol .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 85 (02) :168-173
[8]   Host transmission of Salmonella enterica serovar Typhimurium is controlled by virulence factors and indigenous intestinal microbiota [J].
Lawley, Trevor D. ;
Bouley, Donna A. ;
Hoy, Yana E. ;
Gerke, Christine ;
Relman, David A. ;
Monack, Denise M. . .
INFECTION AND IMMUNITY, 2008, 76 (01) :403-416
[9]   Rapid separation and immunoassay for low levels of Salmonella in foods using magnetosome-antibody complex and real-time fluorescence quantitative PCR [J].
Li, Aihua ;
Zhang, Huiyuan ;
Zhang, Xin ;
Wang, Qi ;
Tian, Jiesheng ;
Li, Ying ;
Li, Jilun .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (21) :3437-3443
[10]   Integrated microfluidic reverse transcription-polymerase chain reaction for rapid detection of food- or waterborne pathogenic rotavirus [J].
Li, Yuyuan ;
Zhang, Chunsun ;
Xing, Da .
ANALYTICAL BIOCHEMISTRY, 2011, 415 (02) :87-96