No long-term psychological morbidity living with an implantable cardioverter defibrillator under advisory: the Medtronic Marquis experience

被引:18
作者
Birnie, David H. [1 ]
Sears, Samuel F. [2 ,3 ]
Green, Martin S. [1 ]
Lemery, Robert [1 ]
Gollob, Michael H. [1 ]
Amyotte, Barbara [1 ]
机构
[1] Univ Ottawa, Inst Heart, Ottawa, ON K1Y 4W7, Canada
[2] E Carolina Univ, Dept Psychol, Greenville, NC 27858 USA
[3] E Carolina Univ, Dept Internal Med Cardiol, Greenville, NC 27858 USA
来源
EUROPACE | 2009年 / 11卷 / 01期
关键词
QUALITY-OF-LIFE; PATIENT ACCEPTANCE SURVEY; RECIPIENTS; PACEMAKER; DISTRESS; THERAPY; RECALL; SHOCKS; IMPACT;
D O I
10.1093/europace/eun317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It is unclear whether there is important psychological morbidity associated with living with an implantable cardioverter defibrillator (ICD) under advisory and whether this should be factored into decision-making. Our study focused on patients living with advisory Medtronic Marquis ICDs. Patient adjustment to the ICD was evaluated using a validated device-specific metric of patient acceptance, the Florida Patient Acceptance Survey (FPAS). A comparison group of patients with other models of ICDs that were not under an advisory also completed the study measure. The questionnaire return rate was 86/122 (70.5%) in the advisory group and 94/134 (70.1%) in the non-advisory group. Only one patient in our clinic elected for generator change due to severe anxiety. There were no differences in demographic or clinical variables between the groups. There were no differences in the mean total FPAS score between the two patient groups (advisory patients 85.97 +/- 14.95 and 86.23 +/- 15.76 for non-advisory, P=0.340). Also there were no differences in any of the subscores. Correlates of poor device acceptance were younger age and a history of electrical storm. We found no evidence of increased long-term psychological morbidity in patients living with an ICD under advisory compared with patients with an ICD not under advisory. Our data suggest that patients and physicians should avoid hasty decisions about ICD replacement for psychological reasons.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 20 条
  • [1] Measuring patient acceptance of implantable cardiac device therapy: Initial psychometric investigation of the Florida Patient Acceptance Survey
    Burns, JL
    Serber, ER
    Keim, S
    Sears, SF
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (04) : 384 - 390
  • [2] Psychological distress in patients with ICD recall
    Cuculi, Florim
    Herzig, Werner
    Kobza, Richard
    Erne, Paul
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (11): : 1261 - 1265
  • [3] How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life?
    Duru, F
    Büchi, S
    Klaghofer, R
    Mattmann, H
    Sensky, T
    Buddeberg, C
    Candinas, R
    [J]. HEART, 2001, 85 (04) : 375 - 379
  • [4] Decision-making, emotional distress, and quality of life in patients affected by the recall of their implantable cardioverter defibrillator
    Gibson, Douglas P.
    Kuntz, Kristin K.
    Levenson, James L.
    Ellenbogen, Kenneth A.
    [J]. EUROPACE, 2008, 10 (05): : 540 - 544
  • [5] Quality of life among implantable cardioverter-defibrillator recipients in the primary prevention therapeutic era
    Groeneveld, Peter W.
    Matta, Mary A.
    Suh, Janice J.
    Yang, Feifei
    Shea, Judy A.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (04): : 463 - 471
  • [6] Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead
    Hauser, Robert G.
    Kallinen, Linda M.
    Almquist, Adrian K.
    Gornick, Charles C.
    Katsiyiannis, William T.
    [J]. HEART RHYTHM, 2007, 4 (07) : 892 - 896
  • [7] Quality of life in the Canadian implantable defibrillator study (CIDS)
    Irvine, J
    Dorian, P
    Baker, B
    O'Brien, BJ
    Roberts, R
    Gent, M
    Newman, D
    Connolly, SJ
    [J]. AMERICAN HEART JOURNAL, 2002, 144 (02) : 282 - 289
  • [8] Electrical storm in patients with an implanted defibrillator: A matter of definition
    Israel, Carsten W.
    Barold, S. Serge
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2007, 12 (04) : 375 - 382
  • [9] Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients
    Leosdottir, M
    Sigurdsson, E
    Reimarsdottir, G
    Gottskalksson, G
    Torfason, B
    Vigfusdottir, M
    Eggertsson, S
    Arnar, DO
    [J]. EUROPACE, 2006, 8 (03): : 168 - 174
  • [10] Pacemaker and ICD generator reliability - Meta-analysis of device registries
    Maisel, WH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16): : 1929 - 1934