Psychological distress in patients with ICD recall

被引:23
作者
Cuculi, Florim [1 ]
Herzig, Werner [1 ]
Kobza, Richard [1 ]
Erne, Paul [1 ]
机构
[1] Kantonsspital Luzern, Dept Cardiol, CH-6000 Luzern 16, Switzerland
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2006年 / 29卷 / 11期
关键词
quality of life; ICD; recall;
D O I
10.1111/j.1540-8159.2006.00523.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Multiple clinical trials have shown that a properly functioning implantable cardioverter-defibrillator (ICD) is capable of interrupting sudden death caused by ventricular tachyarrhythmias. However, ICDs are complex medical devices, and they do not always perform as expected or they may fail completely. Exposure of ICD recipients to professional or media reports that their specific device type is potentially malfunctioning could negatively influence their psychological status. Methods: This study aimed to evaluate and quantify psychological distress in patients implanted with an ICD-recall device. Thirty patients implanted with ICD-recall devices (ICD-recall group) and 25 patients with unaffected ICD devices (ICD-control group) were interviewed using the Brief Symptom Inventory (a psychological self-report symptom scale). Results: Mean values of all primary psychiatric distress symptom dimensions and global indices were within the normal range for both the ICD-recall and the ICD-control group. New York Heart Association (NYHA) class was a predictor of higher distress symptoms in all categories, independently of the ICD group. NYHA II group patients tended toward higher stress levels than the NYHA I group, but only somatization was significantly different. An upward, but not significant, trend in 7 of the 12 scales was associated with symptomatic shock experience. Conclusion: This study demonstrates that psychological distress was not significantly increased in patients recently informed about a potential malfunction of their device.
引用
收藏
页码:1261 / 1265
页数:5
相关论文
共 14 条
  • [1] [Anonymous], 2000, MANUAL G TTINGEN BEL
  • [2] Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators
    Bourke, JP
    Turkington, D
    Thomas, G
    McComb, JM
    Tynan, M
    [J]. HEART, 1997, 78 (06) : 581 - 583
  • [3] Malfunctions in implantable cardiac devices.: Putting the risk in perspective
    Burkhardt, JD
    Wilkoff, BL
    [J]. CLEVELAND CLINIC JOURNAL OF MEDICINE, 2005, 72 (09) : 736 - +
  • [4] Derogatis L.R., 1975, BRIEF SYMPTOM INVENT
  • [5] Lessons from the failure and recall of an implantable cardioverter-defibrillator
    Hauser, RG
    Maron, BJ
    [J]. CIRCULATION, 2005, 112 (13) : 2040 - 2042
  • [6] Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in The United States Food and Drug Administration Manufacturer and User Facility Device Experience Database
    Hauser, RG
    Kallinen, L
    [J]. HEART RHYTHM, 2004, 1 (04) : 399 - 405
  • [7] Unexpected ICD pulse generator failure due to electronic circuit damage caused by electrical overstress
    Hauser, RG
    Hayes, DL
    Almquist, AK
    Epstein, AE
    Parsonnet, V
    Tyers, GFO
    Vlay, SC
    Schoenfeld, MH
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (07): : 1046 - 1054
  • [8] Anxiety and depression in patients receiving implanted cardioverter-defibrillators: A longitudinal investigation
    Hegel, MT
    Griegel, LE
    Black, C
    Goulden, L
    Ozahowski, T
    [J]. INTERNATIONAL JOURNAL OF PSYCHIATRY IN MEDICINE, 1997, 27 (01) : 57 - 69
  • [9] Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients
    Leosdottir, M
    Sigurdsson, E
    Reimarsdottir, G
    Gottskalksson, G
    Torfason, B
    Vigfusdottir, M
    Eggertsson, S
    Arnar, DO
    [J]. EUROPACE, 2006, 8 (03): : 168 - 174
  • [10] Pacemaker and ICD generator malfunctions - Analysis of food and drug administration annual reports
    Maisel, WH
    Moynahan, M
    Zuckerman, BD
    Gross, TP
    Tovar, OH
    Tillman, DB
    Schultz, DB
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16): : 1901 - 1906