Water mapping in hydrated soft materials

被引:25
作者
Sousa, A
Aitouchen, A
Libera, M [1 ]
机构
[1] Stevens Inst Technol, Dept Chem Biomed & Mat Engn, Hoboken, NJ 07030 USA
[2] FEI Co, Tempe, AZ 85282 USA
关键词
electron energy-loss spectroscopy; polymers; scanning transmission electron microscopy; water absorption;
D O I
10.1016/j.ultramic.2005.06.059
中图分类号
TH742 [显微镜];
学科分类号
摘要
We present a method based on spatially resolved electron energy-loss spectroscopy in the cryo-STEM to map the spatial distribution of water in frozen-hydrated polymers. The spatial resolution is limited by the dose constraints imposed by radiation damage, and to stay within these constraints, the use of fine electron-probe sizes comes at the cost of reduced counts in the energy-loss spectra. Thus, at the resolution limit, the detection of isolated water-rich pixels or the identification of minor variations in water content across the specimen is complicated because one must distinguish significant fluctuations from noise. Here we develop a criterion with which to guide such a distinction. We characterize the intrinsic noise associated with spectral measurements under given illumination and acquisition conditions. We then use that noise in combination with scatter diagrams to threshold spectrum images and objectively identify statistically significant compositional fluctuations. We illustrate these ideas using a simulated spectrum dataset for a hypothetical blend of hydrophilic and hydrophobic homopolymers. We show that while a direct inspection of the water map may not allow any meaningful conclusions to be drawn, after applying the thresholding approach we can clearly identify the regions of the specimen that are rich in water. We also experimentally study a model blend system comprised of hydrophilic poly(vinyl pyrrolidone) (PVP) dispersed in a hydrophobic matrix of poly(styrene) (PS). By MLS fitting using damaged and undamaged PVP reference spectra, we determine that the critical dose characteristic of dry PVP is similar to 8000 e/nm(2) using 200 keV incident electrons. Irradiating frozen-hydrated PVP gives rise to noticeable hydrogen evolution at doses of similar to 1500e/nm(2). To stay within this constraint we use doses of 400e/nm(2) and a pixel spacing in the spectrum imaging of 100 nm. In order to quantitatively map the water, PVP, and PS compositions, we measure their total inelastic scattering cross-sections. Direct inspection of the composition maps reveals the presence of large water-rich domains of the order of similar to I mu m and the scatter-diagram thresholding approach identifies small water-rich domains one pixel in size. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 145
页数:16
相关论文
共 51 条
[1]  
AITOUCHEN A, 2002, MICROSC MICROANAL S2, V8, P284
[2]  
AITOUCHEN A, 2001, MICROSC MICROANAL S2, V7, P1168
[3]  
[Anonymous], 1983, Statistical methods
[4]   Sub-angstrom resolution using aberration corrected electron optics [J].
Batson, PE ;
Dellby, N ;
Krivanek, OL .
NATURE, 2002, 418 (6898) :617-620
[5]  
Bright DS, 1998, J MICROSC-OXFORD, V189, P25, DOI 10.1046/j.1365-2818.1998.00249.x
[6]  
BRIGHT DS, 1988, MICROBEAM ANAL, P18
[7]   Mean free paths for inelastic electron scattering in silicon and poly(styrene) nanospheres [J].
Chou, TM ;
Libera, M .
ULTRAMICROSCOPY, 2003, 94 (01) :31-35
[8]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[9]   FROZEN AQUEOUS SUSPENSIONS [J].
DUBOCHET, J ;
CHANG, JJ ;
FREEMAN, R ;
LEPAULT, J ;
MCDOWALL, AW .
ULTRAMICROSCOPY, 1982, 10 (1-2) :55-61
[10]   CRYO-ELECTRON MICROSCOPY OF VITRIFIED SPECIMENS [J].
DUBOCHET, J ;
ADRIAN, M ;
CHANG, JJ ;
HOMO, JC ;
LEPAULT, J ;
MCDOWALL, AW ;
SCHULTZ, P .
QUARTERLY REVIEWS OF BIOPHYSICS, 1988, 21 (02) :129-228