Sub-angstrom resolution using aberration corrected electron optics

被引:711
作者
Batson, PE [1 ]
Dellby, N
Krivanek, OL
机构
[1] IBM Corp, Thomas J Watson Res Ctr, Yorktown Hts, NY 10598 USA
[2] Nion R&D, Kirkland, WA 98033 USA
关键词
D O I
10.1038/nature00972
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Following the invention of electron optics during the 1930s, lens aberrations have limited the achievable spatial resolution to about 50 times the wavelength of the imaging electrons(1). This situation is similar to that faced by Leeuwenhoek in the seventeenth century, whose work to improve the quality of glass lenses led directly to his discovery of the ubiquitous "animalcules" in canal water, the first hints of the cellular basis of life. The electron optical aberration problem was well understood from the start, but more than 60 years elapsed before a practical correction scheme for electron microscopy was demonstrated 2, and even then the remaining chromatic aberrations still limited the resolution. We report here the implementation of a computer-controlled aberration correction system in a scanning transmission electron microscope(3), which is less sensitive to chromatic aberration. Using this approach, we achieve an electron probe smaller than 1 Angstrom. This performance, about 20 times the electron wavelength at 120 keV energy, allows dynamic imaging of single atoms, clusters of a few atoms, and single atomic layer 'rafts' of atoms coexisting with Au islands on a carbon substrate. This technique should also allow atomic column imaging of semiconductors, for detection of single dopant atoms, using an electron beam with energy below the damage threshold for silicon.
引用
收藏
页码:617 / 620
页数:5
相关论文
共 20 条
  • [1] SYMMETRY-SELECTED ELECTRON-ENERGY-LOSS SCATTERING IN DIAMOND
    BATSON, PE
    [J]. PHYSICAL REVIEW LETTERS, 1993, 70 (12) : 1822 - 1825
  • [2] SIMULTANEOUS STEM IMAGING AND ELECTRON-ENERGY-LOSS SPECTROSCOPY WITH ATOMIC-COLUMN SENSITIVITY
    BATSON, PE
    [J]. NATURE, 1993, 366 (6457) : 727 - 728
  • [3] Structural and electronic characterization of a dissociated 60° dislocation in GeSi
    Batson, PE
    [J]. PHYSICAL REVIEW B, 2000, 61 (24) : 16633 - 16641
  • [4] ATOMIC-RESOLUTION CHEMICAL-ANALYSIS USING A SCANNING-TRANSMISSION ELECTRON-MICROSCOPE
    BROWNING, ND
    CHISHOLM, MF
    PENNYCOOK, SJ
    [J]. NATURE, 1993, 366 (6451) : 143 - 146
  • [5] VISIBILITY OF SINGLE ATOMS
    CREWE, AV
    WALL, J
    LANGMORE, J
    [J]. SCIENCE, 1970, 168 (3937) : 1338 - &
  • [6] A SIMPLE SCANNING ELECTRON MICROSCOPE
    CREWE, AV
    ISAACSON, M
    JOHNSON, D
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (02) : 241 - &
  • [7] HIGH RESOLUTION ELECTRON SPECTROMETER FOR USE IN TRANSMISSION SCANNING ELECTRON MICROSCOPY
    CREWE, AV
    ISAACSON, M
    JOHNSON, D
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (04) : 411 - &
  • [8] Progress in aberration-corrected scanning transmission electron microscopy
    Dellby, N
    Krivanek, OL
    Nellist, PD
    Batson, PE
    Lupini, AR
    [J]. JOURNAL OF ELECTRON MICROSCOPY, 2001, 50 (03): : 177 - 185
  • [9] Electron microscopy image enhanced
    Haider, M
    Uhlemann, S
    Schwan, E
    Rose, H
    Kabius, B
    Urban, K
    [J]. NATURE, 1998, 392 (6678) : 768 - 769
  • [10] Development of a 1 MV field-emission transmission electron microscope
    Kawasaki, T
    Matsui, I
    Yoshida, T
    Katsuta, T
    Hayashi, S
    Onai, T
    Furutsu, T
    Myochin, K
    Numata, M
    Mogaki, H
    Gorai, M
    Akashi, T
    Kamimura, O
    Matsuda, T
    Osakabe, N
    Tonomura, A
    Kitazawa, K
    [J]. JOURNAL OF ELECTRON MICROSCOPY, 2000, 49 (06) : 711 - 718