Reliability and economic evaluation of small autonomous power systems containing only renewable energy sources

被引:49
作者
Georgilakis, Pavlos S. [1 ]
Katsigiannis, Yiannis A. [1 ]
机构
[1] Tech Univ Crete, Dept Prod Engn & Management, GR-73100 Khania, Greece
关键词
Autonomous power systems; Reliability cost; Reliability worth; Renewable energy sources; Sensitivity analysis; COST;
D O I
10.1016/j.renene.2008.03.004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Evaluation of reliability performance in every power system has to be done within a cost-benefit framework. This approach, however, is a very time consuming task, especially for systems that contain a large number of possible configurations, so simpler techniques referred to the calculation of reliability indices are used. In small autonomous power systems (SAPSs), such an evaluation uses mainly deterministic criteria. This approach, however, cannot be applied in SAPS that contain only renewable energy sources, due to the intermittent nature of the provided energy. In this paper, a complete reliability cost and worth analysis is implemented for these systems, combined with the calculation of some basic probabilistic indices, in order to discover their performance and propose the appropriate of them as a criterion of optimal system configuration. This paper proposes that normalized energy reliability indices as system minutes and energy index of unavailability can be used as adequate criteria of system's optimal performance. This conclusion is validated through a large number of sensitivity analysis studies that are based on different maximum annual loads and different mix of load types. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 21 条
[11]   Energy balance analysis of a stand-alone photovoltaic system, including variable system reliability impact [J].
Kaldellis, JK ;
Koronakis, P ;
Kavadias, K .
RENEWABLE ENERGY, 2004, 29 (07) :1161-1180
[12]  
KARIUKI KK, 1995, P CIRED 95
[13]   Cost-effective wind energy utilization for reliable power supply [J].
Karki, R ;
Billinton, R .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (02) :435-440
[14]  
KOSKOLOS NC, 1998, P ICHQP 98 ATH GREE
[15]  
*NEWF LABR HYDR, 1995, IS SYST GEN PLANN PR
[16]  
SwiftHook DT, 1997, RENEW ENERG, V10, P247
[17]   THE VALUE OF STORAGE ON POWER-SYSTEMS WITH INTERMITTENT ENERGY-SOURCES [J].
SWIFTHOOK, DT ;
TERGAZARIAN, AG .
RENEWABLE ENERGY, 1994, 5 (5-8) :1479-1482
[18]   Reliability modeling and analysis of stand-alone PEM fuel cell power plants [J].
Tanrioven, M ;
Alam, MS .
RENEWABLE ENERGY, 2006, 31 (07) :915-933
[19]   A CANADIAN CUSTOMER SURVEY TO ASSESS POWER-SYSTEM RELIABILITY WORTH [J].
TOLLEFSON, G ;
BILLINTON, R ;
WACKER, G ;
CHAN, E ;
AWEYA, J .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (01) :443-450
[20]   Development of an experimental investigation procedure on double fed electric machine-based actuator for wind power systems [J].
Vernados, PG ;
Katiniotis, IM ;
Ioannides, MG .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 106 (1-3) :302-305