Occupational exposure to polycyclic aromatic hydrocarbons in a fireproof stone producing plant:: biological monitoring of 1-hydroxypyrene, 1-, 2-, 3- and 4-hydroxyphenanthrene, 4-hydroxybenz(a)anthracene and 3-hydroxybenzo(a)pyrene

被引:56
作者
Gündel, J [1 ]
Schaller, KH [1 ]
Angerer, J [1 ]
机构
[1] Inst & Outpatient Clin Occupat Social & Environm, D-91054 Erlangen, Germany
关键词
polycyclic aromatic hydrocarbons; urinary metabolites; biological monitoring; fireproof stone production;
D O I
10.1007/s004200050427
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: Assessment of external and internal exposure to polycyclic aromatic hydrocarbons (PAH) in a fireproof stone producing plant. Methods: Five personal and four stationary air measurements were performed to determine the concentrations of benz(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, chrysene, dibenz(a,h)anthracene, fluoranthene, phenanthrene and pyrene, in air. To estimate internal exposure, we determined the urinary excretion of 1-hydroxypyrene. 1-, 2-, 3-, and 4-hydroxyphenanthrene. 3-hydroxybenz(a)anthracene and 3-hydroxybenzo(a)pyrene in 19 workers, using a sensitive and reliable high-performance liquid chromatographic method with fluorescence detection. Results: During the production of fireproof stones. the German technical exposure limit (TRK) for benzo(a)pyrene of 2 mu g/m(3) was exceeded in two cases. The mean values of the sum of eight PAHs were 12.6 mu g/m(3) (stationary air measurement) and 22.2 mu g/m(3) (personal air measurement). Urinary I-hydroxypyrene excretion predominated, with a median of 11.1 mu g/g creatinine (creat.), followed by 3-hydroxyphenanthrene (median 2.2 mu g/g creat.), 1-hydroxyphenanthrene (median 1.9 mu g/g creat.) and 2-hydroxyphenanthrene (median 1.6 mu g/g creat.). 4-Hydroxyphenanthrene (median 0.3 mu g/g creat.) and 3-hydroxybenz(a)anthracene (median 0.17 mu g/g creat.) were found in far lower concentrations. while 3-hydroxybenzo(a)pyrene was found only in very low concentrations (median 0.014 mu g/g creat.). No correlations could be detected for a relationship between external and internal exposure. A significant correlation between urinary metabolite concentrations could be calculated only for 3-hydroxybenz(a)anthracene and 1-hydroxypyrene. Conclusions:: In comparison with other industries, the internal PAH exposure at workplaces in a fireproof stone producing plant is high. This is probably caused by dermal PAM-absorption. Therefore, biological monitoring must be performed in the health surveillance of fireproof stone producing workers. The urinary PAH metabolites should be determined: 3-hydroxybenz(a)anthracene could probably be used as a biomarker representing the group of carcinogenic PAM.
引用
收藏
页码:270 / 274
页数:5
相关论文
共 21 条
[1]  
Angerer J, 1997, INT ARCH OCC ENV HEA, V69, P323
[2]   Biological monitoring and biochemical effect monitoring of exposure to polycyclic aromatic hydrocarbons [J].
Angerer, J ;
Mannschreck, C ;
Gundel, J .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1997, 70 (06) :365-377
[3]   TRACE ANALYSIS OF 3-HYDROXY BENZO[A]PYRENE IN URINE FOR THE BIOMONITORING OF HUMAN EXPOSURE TO POLYCYCLIC AROMATIC-HYDROCARBONS [J].
ARIESE, F ;
VERKAIK, M ;
HOORNWEG, GP ;
VANDENESSE, RJ ;
UKEMALEENSTRA, SR ;
HOFSTRAAT, JW ;
GOOIJER, C ;
VELTHORST, NH .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (04) :195-204
[4]  
Association Advancing Occupational and Environmental Health (ACGIH), 1999, THRESH LIM VAL CHEM
[5]   COUPLED-COLUMN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF 1-HYDROXYPYRENE IN URINE OF SUBJECTS EXPOSED TO POLYCYCLIC AROMATIC-HYDROCARBONS [J].
BOOS, KS ;
LINTELMANN, J ;
KETTRUP, A .
JOURNAL OF CHROMATOGRAPHY, 1992, 600 (02) :189-194
[6]   Urinary 1-hydroxypyrene as a biomarker of exposure to polycyclic aromatic hydrocarbons: biological monitoring strategies and methodology for determining biological exposure indices for various work environments [J].
Bouchard, M ;
Viau, C .
BIOMARKERS, 1999, 4 (03) :159-187
[7]  
*DFG, 1999, 35 DFG
[8]  
GRIMMER G, 1992, ACT 4 COLL INT COM R
[9]  
GRIMMER G, 1992, GIT FACHZ LAB, V1, P12
[10]   High-performance liquid chromatographic method with fluorescence detection for the determination of 3-hydroxybenzo[a]pyrene and 3-hydroxybenz[a]anthracene in the urine of polycyclic aromatic hydrocarbon-exposed workers [J].
Gündel, J ;
Angerer, J .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (01) :47-55