A 4-channel wearable wireless neural recording system

被引:15
作者
Chae, Moosung [1 ]
Chen, Kuanfu [1 ]
Liu, Wentai [1 ]
Kim, Jungsuk [1 ]
Sivaprakasam, Mohanasankar [1 ]
机构
[1] Univ Calif Santa Cruz, Integrated Bioelect Res Grp, Santa Cruz, CA 95064 USA
来源
PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10 | 2008年
关键词
D O I
10.1109/ISCAS.2008.4541779
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a 4-channel wearable wireless neural recording system that consists of wireless head stage, receiver board, and user interface software. The wireless head stage is implemented using a custom designed font-end IC for bio potential amplification, filtering, and channel selection and a commercial analog FM transmitter chip. Adjustable gain and bandwidth of the channel allows the system to be used in recording various neural signals. The size of the head stage is 1.55" x 1.725" x 0.5" and the weight is 20g. The power consumption of the head stage is 28mW from two 1.55V button cell batteries that allows continuous operation of at least 15 hours. The system was tested for ex-vivo and in-vivo extracellular recordings from a dissected snail brain and a live rat respectively.
引用
收藏
页码:1760 / 1763
页数:4
相关论文
共 7 条
[1]   Wireless, in vivo neural recording using a custom integrated bioamplifier and the pico system [J].
Cheney, David ;
Goh, Aik ;
Xu, Jie ;
Gugel, Karl ;
Harris, John G. ;
Sanchez, Justin C. ;
Principe, Jose C. .
2007 3RD INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, VOLS 1 AND 2, 2007, :19-+
[2]   An embedded system architecture for wireless neural recording [J].
Farshchi, Shahin ;
Pesterev, Aleksey ;
Guenterberg, Eric ;
Mody, Istvan ;
Judy, Jack W. .
2007 3RD INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, VOLS 1 AND 2, 2007, :327-+
[3]   A design and construction of 4 channel biotelemetry device employing indoor [J].
Fidan, Ugur ;
Guler, Nihal Fatma .
JOURNAL OF MEDICAL SYSTEMS, 2007, 31 (03) :159-165
[4]   A low-power low-noise CMOS amplifier for neural recording applications [J].
Harrison, RR ;
Charles, C .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (06) :958-965
[5]   In-Vivo EEG recording using a wireless implantable neural transceiver [J].
Irazoqui-Pastor, P ;
Mody, I ;
Judy, JW .
1ST INTERNATIONAL IEEE EMBS CONFERENCE ON NEURAL ENGINEERING 2003, CONFERENCE PROCEEDINGS, 2003, :622-625
[6]  
MOHSENI P, 2005, SOL STAT CIRC C 2005, P560
[7]   Miniature stereo radio transmitter for simultaneous recording of multiple single-neuron signals from behaving owls [J].
Nieder, A .
JOURNAL OF NEUROSCIENCE METHODS, 2000, 101 (02) :157-164