Comparison between sirolimus-eluting stents and intracoronary catheter-based beta radiation for the treatment of in-stent restenosis

被引:23
作者
Feres, F [1 ]
Muñoz, JS
Abizaid, A
Albertal, M
Mintz, GS
Staico, R
Centemero, M
Mattos, LA
Maldonado, G
Tanajura, LF
Chaves, A
Pinto, I
Abizaid, AS
Seixas, AC
Vaz, VD
Sousa, A
Sousa, JE
机构
[1] Inst Dante Pazzanese Cardiol, Sao Paulo, Brazil
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
D O I
10.1016/j.amjcard.2005.07.081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report the outcomes of patients who had in-stent restenosis (IRS) that was treated with intravascular brachytherapy (IVBT) or sirolimus-eluting stent (SES) implantation. The benefit of IVBT for treating ISR is well documented. SES implantation decreases first-time ISR and, in preliminary reports, has been used to treat ISR. Fifty consecutive patients who had ISR were treated; the first 25 patients underwent SES implantation and the next 25 patients were treated with IVBT using a beta-Cath System (a 40-mm strontium-90/yttrium-90 source). Quantitative angiographic and intravascular ultrasound follow-up were performed at 5.2 +/- 1.1 and 12.1 +/- 1.2 months; clinical follow-up was performed at 15 months. SES deployment and IVBT were successful in all patients. At 12-month follow-up, 8 patients who underwent IVBT had angiographic recurrence (4 in the stent and 4 at the stent edge); only 1 patient who underwent SES implantation developed recurrent ISR. At 12 months, in-stent late luminal loss was similar between the SES and IVBT,groups (0.35 +/- 0.45 vs 0.34 +/- 0.46 mm, p = 0.9); however, in-stent net luminal gain was higher in the SES group than in the IVBT group (1.32 +/- 0.13 vs 0.57 +/- 0.19 mm, p <0.0001), and in-lesion late luminal loss was higher in the IVBT group (0.48 +/- 0.32 vs 0.16 +/- 0.42 mm, p = 0.004). At 12 months, intravascular ultrasound stent volume obstruction was higher after IVBT versus than after SES implantation (38.7% vs 6.7%, p <0.0001). At 15-month clinical follow-up, 64% and 96% (p <0.01) of patients who underwent IVBT and SES implantation, respectively, were free of major adverse cardiac events. In conclusion SES implantation for the treatment of ISR was effective and superior to catheter-based IVBT in preventing recurrent neointimal proliferation and angiographic restenosis at 1-year follow-up. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1656 / 1662
页数:7
相关论文
共 28 条
[1]   A randomized comparison of repeat stenting with balloon angioplasty in patients with in-stent restenosis [J].
Alfonso, F ;
Zueco, J ;
Cequier, A ;
Mantilla, R ;
Bethencourt, A ;
López-Minguez, JR ;
Angel, J ;
Augé, JM ;
Gómez-Recio, M ;
Morís, C ;
Seabra-Gomes, R ;
Perez-Vizcayno, MJ ;
Macaya, C .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (05) :796-805
[2]   Sirolimus-eluting stent for treatment of complex in-stent restenosis - The first clinical experience [J].
Degertekin, M ;
Regar, E ;
Tanabe, K ;
Smits, PC ;
van der Giessen, WJ ;
Carlier, SG ;
de Feyter, P ;
Vos, J ;
Foley, DP ;
Ligthart, JMR ;
Popma, JJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (02) :184-189
[3]   Is sirolimus-eluting stent better than brachytherapy to treat in-stent restenosis at longer (12-month) follow-up?: Angiographic and intravascular ultrasound analysis [J].
Feres, F ;
Muñoz, JS ;
Abizaid, A ;
Staico, R ;
Mattos, LA ;
Maldonado, G ;
Centemero, M ;
Pinto, I ;
Abizaid, AS ;
Chaves, A ;
Tanajura, LF ;
Sousa, A ;
Sousa, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :70A-70A
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis [J].
Fujii, K ;
Mintz, GS ;
Kobayashi, Y ;
Carlier, SG ;
Takebayashi, H ;
Yasuda, T ;
Moussa, I ;
Dangas, G ;
Mehran, R ;
Lansky, AJ ;
Reyes, A ;
Kreps, E ;
Collins, M ;
Colombo, A ;
Stone, GW ;
Teirstein, PS ;
Leon, MB ;
Moses, JW .
CIRCULATION, 2004, 109 (09) :1085-1088
[6]   Predictors of diffuse and aggressive intra-stent restenosis [J].
Goldberg, SL ;
Loussararian, A ;
De Gregorio, J ;
Di Mario, C ;
Albiero, R ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) :1019-1025
[7]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[8]   Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis -: A randomized controlled trial [J].
Kastrati, A ;
Mehilli, J ;
von Beckerath, N ;
Dibra, A ;
Hausleiter, J ;
Pache, J ;
Schühlen, H ;
Schmitt, C ;
Dirschinger, J ;
Schömig, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (02) :165-171
[9]  
Kay IP, 2001, CIRCULATION, V103, P14
[10]   Three-dimensional intravascular ultrasound assessment of noninjured edges of β-irradiated coronary segments [J].
Kozuma, K ;
Costa, MA ;
Sabaté, M ;
Kay, IP ;
Marijnissen, JPA ;
Coen, VLMA ;
Serrano, P ;
Ligthart, JMR ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 2000, 102 (13) :1484-1489