Evaluation of a benchtop ion trap gas chromatographic tandem mass spectrometric instrument for the analysis of a model drug, tebufelone, in plasma using a stable-isotope internal standard

被引:21
作者
Wehmeyer, KR [1 ]
Knight, PM [1 ]
Parry, RC [1 ]
机构
[1] VARIAN ANALYT INSTRUMENTS,WOOD DALE,IL 60191
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 676卷 / 01期
关键词
tandem mass spectrometry; ion trap GC-MS-MS instrument; tebufelone;
D O I
10.1016/0378-4347(95)00417-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a benchtop GC-ion trap MS-MS instrument, the Varian Saturn 4D, was evaluated for the analysis of a model drug, tebufelone, in plasma. The sample preparation scheme was designed to provide a highly complex extract with matrix-derived interferences eluting near and at the retention time of tebufelone and its stable-isotope-labeled analog. The performance of the ion trap in the selected-reaction-monitoring mode was evaluated and also compared with results obtained on a benchtop GC-MS linear quadrupole instrument operated in the selected-ion-monitoring mode. The ion trap, operated in the selected-reaction-monitoring mode, was found to provide a higher degree of selectivity for the analysis of tebufelone. The increased selectivity obtained on the ion trap operated in the selected-reaction-monitoring mode resulted in superior accuracy and precision, as well as a Lower limit of quantitation relative to that obtained by the GC-MS analysis. A linear standard curve was obtained over three orders of magnitude and the limit of quantitation for tebufelone in plasma was 100 pg/ml using the GC-ion trap MS-MS instrument.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 9 条
[1]   DEVELOPMENT AND APPLICATION OF A GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC MASS-SPECTROMETRIC METHOD FOR THE DETERMINATION OF 5-METHOXYFLAVONE IN RAT AND DOG PLASMA [J].
BAKER, TR ;
WEHMEYER, KR ;
KELM, GR ;
TULICH, LJ ;
KUHLENBECK, DL ;
DOBROZSI, DJ ;
PENAFIEL, JV .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (03) :438-445
[2]   LONG-TERM PERFORMANCE OF A GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY ASSAY FOR TEBUFELONE IN PLASMA [J].
DOBSON, RLM ;
NEAL, DM ;
DEMARK, BR ;
WARD, SR .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1819-1824
[3]  
DOYLE MJ, 1993, J PHARM SCI, V82, P1
[4]   TANDEM MASS-SPECTROMETRY FOR TRACE ANALYSIS [J].
JOHNSON, JV ;
YOST, RA .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :A758-&
[5]   ION TRAP MASS-SPECTROMETRY [J].
MARCH, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 118 :71-135
[6]   ASPECTS OF RECENT DEVELOPMENTS IN ION-TRAP MASS-SPECTROMETRY [J].
NOURSE, BD ;
COOKS, RG .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :1-21
[7]   COMBINED CAPILLARY GAS-CHROMATOGRAPHY ION TRAP MASS-SPECTROMETRY QUANTITATIVE METHODS USING LABELED OR UNLABELED INTERNAL STANDARDS [J].
STRIFE, RJ ;
SIMMS, JR ;
LACEY, MP .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (03) :265-271
[8]   QUANTITATIVE-ANALYSIS OF CRUDE PLASMA EXTRACTS BY ION TRAP TANDEM MASS-SPECTROMETRY [J].
STRIFE, RJ ;
SIMMS, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :372-377
[9]  
YACOBI A, 1989, TOXICOKINETICS NEW D