Conformational effects on cationization of poly(ethylene glycol) by alkali metal ions in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:18
作者
Shimada, K
Matsuyama, S
Saito, T
Kinugasa, S
Nagahata, R
Kawabata, S
机构
[1] AIST, Natl Metrol Inst Japan, Organ Analyt Chem Div, Polymer Stand Sect, Tsukuba, Ibaraki 3058565, Japan
[2] AIST, Res Inst Innovat Sustainable Chem, Tsukuba, Ibaraki 3058565, Japan
[3] Shimadzu Co Ltd, Tokyo, Japan
关键词
MALDI-TOFMS; molecular dynamics; poly(ethylene glycol); uniform oligomer; alkali metal ion;
D O I
10.1016/j.ijms.2005.10.001
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Conformational effects of polymer chains on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) were studied by using an equimolar mixture of uniform poly(ethylene glycol)s (PEGs) and by molecular dynamics simulations. Uniform PEGs with degrees of polymerization n = 8-39 were separated from commercial PEG samples by preparative supercritical fluid chromatography. MALDI-TOFMS spectra of an equimolar mixture of the uniform PEGs in aqueous ethanol were measured by adding a mixture of 2,5-dihydroxybenzoic acid (as a matrix reagent) and five alkali metal chlorides (LiCl, NaCl, KCl, RbCl, and CsCl). After optimization of the matrix concentration and laser power, five types of adduct cationized by Li+, Na+, K+, Rb+, and Cs+ could be identified simultaneously in the same spectrum. In the lower molecular-mass region around 103, the spectral intensity increase rapidly with increasing molecular mass of PEG; this rapid increase in the spectral intensity started at a lower molecular mass for smaller adduct cations. Molecular dynamics simulations were used to calculated the affinity of PEG for the adduct cations. These experimental and simulated results showed that the observed spectral intensities in MALDI-TOFMS were markedly affected by the species of adduct cations and the degree of polymerization of the PEG, and that they were dependent on the stability of the PEG-cation complex. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 43 条
[1]   Mass discrimination effects in an ion detector and other causes for shifts in polymer mass distributions measured by matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Axelsson, J ;
Scrivener, E ;
Haddleton, DM ;
Derrick, PJ .
MACROMOLECULES, 1996, 29 (27) :8875-8882
[2]  
Dogruel D, 1996, RAPID COMMUN MASS SP, V10, P801
[3]   The desorption process in MALDI [J].
Dreisewerd, K .
CHEMICAL REVIEWS, 2003, 103 (02) :395-425
[4]   MALDI-TOF-MS of saturated polyolefins by coordination of metal cations: A theoretical study [J].
Ehlers, AW ;
de Koster, CG ;
Meier, RJ ;
Lammertsma, K .
JOURNAL OF PHYSICAL CHEMISTRY A, 2001, 105 (38) :8691-8695
[5]   Poly (Ethylene terephthalate) oligomers cationized by alkali ions: Structures, energetics, and their effect on mass spectra and the matrix-assisted laser desorption/ionization process [J].
Gidden, J ;
Wyttenbach, T ;
Batka, JJ ;
Weis, P ;
Jackson, AT ;
Scrivens, JH ;
Bowers, MT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (09) :883-895
[6]   NIST-sponsored interlaboratory comparison of polystyrene molecular mass distribution obtained by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: Statistical analysis [J].
Guttman, CM ;
Wetzel, SJ ;
Blair, WR ;
Fanconi, BM ;
Girard, JE ;
Goldschmidt, RJ ;
Wallace, WE ;
VanderHart, DL .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1252-1262
[7]   A simple, low-cost, air-spray method for improved sample preparation for matrix-assisted laser desorption/ionisation mass spectrometry of derivatised poly(ethylene glycol) - Comment [J].
Haddleton, DM ;
Waterson, C ;
Derrick, PJ .
EUROPEAN MASS SPECTROMETRY, 1998, 4 (03) :203-207
[8]   Investigations of matrix-assisted laser desorption/ionization sample preparation by time-of-flight secondary ion mass spectrometry [J].
Hanton, SD ;
Clark, PAC ;
Owens, KG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (02) :104-111
[9]   Investigations of electrospray sample deposition for polymer MALDI mass spectrometry [J].
Hanton, SD ;
Hyder, IZ ;
Stets, JR ;
Owens, KG ;
Blair, WR ;
Guttman, CM ;
Giuseppetti, AA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (02) :168-179
[10]   The effect of counter ions in matrix-assisted laser desorption/ionization of poly(methyl methacrylate) [J].
Hoberg, AM ;
Haddleton, DM ;
Derrick, PJ ;
Jackson, AT ;
Scrivens, JH .
EUROPEAN MASS SPECTROMETRY, 1998, 4 (06) :435-440