Effect of viscous loss on mechanical resonators designed for mass detection

被引:76
作者
Vignola, JF
Judge, JA
Jarzynski, J
Zalalutdinov, M
Houston, BH
Baldwin, JW
机构
[1] USN, Res Lab, Washington, DC 20375 USA
[2] Catholic Univ Amer, Dept Mech Engn, Washington, DC 20064 USA
[3] SFA Inc, Largo, MD 20774 USA
关键词
Oscillations - Vibrations (mechanical) - Viscous flow;
D O I
10.1063/1.2165186
中图分类号
O59 [应用物理学];
学科分类号
摘要
Simple models are presented for estimating viscous damping of fluid (gas or liquid) loaded mechanical resonators. The models apply to beams in flexural modes of vibration, and to thin beams and plates in longitudinal modes of vibration. Predictions of the associated quality factor are compared with measured values for several macroscale and microscale resonators. The scaling of viscous loss with oscillator size is discussed. The minimum detectable mass is estimated for several oscillator designs and it is shown that, for comparably sized devices, longitudinal resonators have the lowest threshold of detection. This minimum detectable mass is proportional to scale to the power 1.75 for all resonator architectures limited by viscous damping, and it is shown that the viscous loss is 220 times larger in water than in air. (c) 2006 American Institute of Physics.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 11 条
[1]   Effect of fluids on the Q factor and resonance frequency of oscillating micrometer and nanometer scale beams -: art. no. 036307 [J].
Bhiladvala, RB ;
Wang, ZJ .
PHYSICAL REVIEW E, 2004, 69 (03) :036307-1
[2]   DEPENDENCE OF THE QUALITY FACTOR OF MICROMACHINED SILICON BEAM RESONATORS ON PRESSURE AND GEOMETRY [J].
BLOM, FR ;
BOUWSTRA, S ;
ELWENSPOEK, M ;
FLUITMAN, JHJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (01) :19-26
[3]  
EKINCI K, 2004, J APPL PHYS, V95, P3694
[4]   Ultrasensitive nanoelectromechanical mass detection [J].
Ekinci, KL ;
Huang, XMH ;
Roukes, ML .
APPLIED PHYSICS LETTERS, 2004, 84 (22) :4469-4471
[5]  
Hansen ST, 2000, ULTRASON, P947, DOI 10.1109/ULTSYM.2000.922697
[6]  
HOUSTON BH, 2004, MAT SCI ENG A-STRUCT, V407, P370
[7]   Attogram detection using nanoelectromechanical oscillators [J].
Ilic, B ;
Craighead, HG ;
Krylov, S ;
Senaratne, W ;
Ober, C ;
Neuzil, P .
JOURNAL OF APPLIED PHYSICS, 2004, 95 (07) :3694-3703
[8]  
LANDAU L, 2003, 12 INT C SOL STAT SE, P947
[9]   Cantilever transducers as a platform for chemical and biological sensors [J].
Lavrik, NV ;
Sepaniak, MJ ;
Datskos, PG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07) :2229-2253
[10]   Attachment losses of high Q oscillators [J].
Photiadis, DM ;
Judge, JA .
APPLIED PHYSICS LETTERS, 2004, 85 (03) :482-484