Fast flow-injection fluorimetric determination of amiloride by using a solid sensing zone

被引:24
作者
Domínguez-Vidal, A [1 ]
Ortega-Barrales, P [1 ]
Molina-Díaz, A [1 ]
机构
[1] Univ Jaen, Dept Phys & Analyt Chem, Fac Expt Sci, Jaen 23071, Spain
关键词
amiloride determination; fluorimetric sensor; pharmaceuticals and biological fluids; serum;
D O I
10.1016/S0039-9140(01)00586-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple flow-through solid phase spectrofluorimetric system is described in this paper for the determination of the diuretic amiloride in physiological fluid (serum) and pharmaceuticals. The sensor was developed in conjunction with a monochannel flow-injection analysis system with fluorimetric transduction. Amiloride was transitorily retained on cationic exchanger gel Sephadex SP-C25 placed in the detection area into the cell. The determination is carried out without any derivatization reaction, by measuring directly the intrinsic fluorescence of the analyte and using the peak height as analytical signal. The wavelengths of excitation and emission were 291 and 419 nm, respectively. Amiloride could be determined in the concentration ranges of 10-600 and 4-250 mug l(-1) at a sampling rate of 24 and 30 h(-1), respectively with detection limits of 0.92 and 0.33 mug l(-1) for 100, and 600 mul of sample volume injected, respectively. The relative standard deviations for ten independent determinations were better than 0.65%. The method was satisfactorily applied to the determination of amiloride in spiked biological fluids (serum) and pharmaceutical preparations without any pretreatment of the samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1005 / 1013
页数:9
相关论文
共 23 条
[1]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[2]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[3]   A selective optosensor for UV spectrophotometric determination of thiamine in the presence of other vitamins B [J].
Barrales, PO ;
de Córdova, MLF ;
Díaz, AM .
ANALYTICA CHIMICA ACTA, 1998, 376 (02) :227-233
[4]   ELECTROCHEMICAL DETERMINATION OF THE LOOP DIURETICS PIRETANIDE AND FUROSEMIDE IN PHARMACEUTICAL FORMULATIONS AND URINE [J].
BARROSO, MB ;
ALONSO, RM ;
JIMENEZ, RM .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :332-339
[5]  
Bonet-Domingo E., 1992, ANALYST, V117, P843
[6]   COLUMN-SWITCHING TECHNIQUES FOR SCREENING OF DIURETICS AND PROBENECID IN URINE SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :244-248
[7]   Chromatographic determination of diuretics in urine samples using hybrid micellar mobile phases with fluorimetric detection [J].
Carda-Broch, S ;
Esteve-Romero, JS ;
García-Alvarez-Coque, MC .
ANALYTICA CHIMICA ACTA, 1998, 375 (1-2) :143-154
[8]   FLOW-THROUGH SENSOR FOR THE FLUOROMETRIC-DETERMINATION OF CYANIDE [J].
CHEN, DH ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1990, 37 (11) :1049-1055
[9]   Direct determination of diuretic drugs in urine by capillary zone electrophoresis using fluorescence detection [J].
Gonzalez, E ;
Becerra, A ;
Laserna, JJ .
JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01) :145-150
[10]  