摘要
MR susceptometry-based blood oximetry relies on phase mapping to measure the difference in magnetic susceptibility between intravascular blood and surrounding tissue. The main source of error in MR susceptometry is the static field inhomogeneity caused by an interface between air and tissue or between adjacent tissue types. High-pass filtering has previously been used in conjunction with shimming to reduce the effect of low spatial-frequency modulations of the phase caused by large-scale induced magnetic fields. We demonstrate that high-pass filtering is not optimum for MR susceptometry because the results are sensitive to filter size. We propose an alternative method that acquires data without scanner-implemented default shimming, and fits, after appropriate weighting and masking, the static field inhomogeneity to a second-order polynomial. Compared to shimming the retrospective correction technique improved agreement between hemoglobin saturations measured in different segments of a vessel (femoral versus popliteal artery and vein) from three standard errors to less than one. Magn Reson Med 61:626-633, 2008. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:626 / 633
页数:8
相关论文
共 25 条
[1]   Diving response and arterial oxygen saturation during apnea and exercise in breath-hold divers [J].
Andersson, JPA ;
Linér, MH ;
Rünow, E ;
Schagatay, EKA .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (03) :882-886
[2]  
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[3]  
[Anonymous], 1988, Classical Electrodynamics
[4]   Magnetic susceptibility: Further insights into macroscopic and miroscopic fields and the sphere of lorentz [J].
Durrant, CJ ;
Hertzberg, MP ;
Kuchel, PW .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2003, 18A (01) :72-95
[5]   MR susceptometry for measuring global brain oxygen extraction [J].
Fernández-Seara, MA ;
Techawiboonwong, A ;
Detre, JA ;
Wehrli, FW .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :967-973
[6]  
Feynman R., 1963, The Feynman Lectures on Physics, VII
[7]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[8]  
Haacke E.M., 1999, Magnetic Resonance Imaging: Physical Principles and Sequence Design
[9]  
Haacke EM, 1997, HUM BRAIN MAPP, V5, P341, DOI 10.1002/(SICI)1097-0193(1997)5:5<341::AID-HBM2>3.0.CO
[10]  
2-3