MR susceptometry for measuring global brain oxygen extraction

被引:136
作者
Fernández-Seara, MA
Techawiboonwong, A
Detre, JA
Wehrli, FW
机构
[1] Univ Penn, Dept Radiol, Lab Struct NMR Imaging, Med Ctr, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, Ctr Funct Neuroimaging, Med Ctr, Philadelphia, PA 19104 USA
关键词
mRI; oxygen saturation; field mapping; jugular vein; phase imaging;
D O I
10.1002/mrm.20892
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Monitoring of oxygen saturation in jugular venous blood gives an estimate of the balance of global oxygen delivery and cerebral oxygen consumption. We present a noninvasive approach to measure oxygen saturation in vivo in the internal jugular vein using MR susceptometry by exploiting the characteristic susceptibility of deoxyhemoglobin, and demonstrate the feasibility of performing such measurements in a group of subjects. We assessed the sensitivity of the method for detecting small changes in oxygen saturation by monitoring the variations observed during breath-holding and hypoventilation experiments. Unlike alternative methods, the susceptometric technique does not require calibration.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 32 条
[1]   Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging [J].
An, HY ;
Lin, WL .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (08) :1225-1236
[2]   Diving response and arterial oxygen saturation during apnea and exercise in breath-hold divers [J].
Andersson, JPA ;
Linér, MH ;
Rünow, E ;
Schagatay, EKA .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (03) :882-886
[3]   Normal jugular bulb oxygen saturation [J].
Chieregato, A ;
Calzolari, F ;
Trasforini, G ;
Targa, L ;
Latronico, N .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2003, 74 (06) :784-786
[4]   Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry [J].
Daubeney, PEF ;
Pilkington, SN ;
Janke, E ;
Charlton, GA ;
Smith, DC ;
Webber, SA .
ANNALS OF THORACIC SURGERY, 1996, 61 (03) :930-934
[5]   Arterial oxygen saturation and heart rate variation during breath-holding:: comparison between breath-hold divers and controls [J].
Delahoche, J ;
Delapille, P ;
Lemaître, F ;
Verin, E ;
Tourny-Chollet, C .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (03) :177-181
[6]  
DellaCorte F, 1996, NEUROSURGERY, V39, P390
[7]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[8]   MR susceptometry for measuring global brain oxygen extraction [J].
Fernández-Seara, MA ;
Techawiboonwong, A ;
Detre, JA ;
Wehrli, FW .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :967-973
[9]   CENTRAL VENOUS O-2 SATURATION AND RATE OF ARTERIAL DESATURATION DURING OBSTRUCTIVE APNEA [J].
FLETCHER, EC ;
KASS, R ;
THORNBY, JI ;
ROSBOROUGH, J ;
MILLER, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (03) :1477-1485
[10]  
FRICKHOFEN N, 1991, INN MED, P173