MR susceptometry for measuring global brain oxygen extraction

被引:136
作者
Fernández-Seara, MA
Techawiboonwong, A
Detre, JA
Wehrli, FW
机构
[1] Univ Penn, Dept Radiol, Lab Struct NMR Imaging, Med Ctr, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, Ctr Funct Neuroimaging, Med Ctr, Philadelphia, PA 19104 USA
关键词
mRI; oxygen saturation; field mapping; jugular vein; phase imaging;
D O I
10.1002/mrm.20892
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Monitoring of oxygen saturation in jugular venous blood gives an estimate of the balance of global oxygen delivery and cerebral oxygen consumption. We present a noninvasive approach to measure oxygen saturation in vivo in the internal jugular vein using MR susceptometry by exploiting the characteristic susceptibility of deoxyhemoglobin, and demonstrate the feasibility of performing such measurements in a group of subjects. We assessed the sensitivity of the method for detecting small changes in oxygen saturation by monitoring the variations observed during breath-holding and hypoventilation experiments. Unlike alternative methods, the susceptometric technique does not require calibration.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 32 条
[21]   DEMAGNETIZING FACTORS OF THE GENERAL ELLIPSOID [J].
OSBORN, JA .
PHYSICAL REVIEW, 1945, 67 (11-1) :351-357
[22]   Single-shot magnetic field mapping embedded in echo-planar time-course imaging [J].
Roopchansingh, V ;
Cox, RW ;
Jesmanowicz, A ;
Ward, BD ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :839-843
[23]  
SAHA P, 2005, P SPIE MED IM SAN DI, P1544
[24]   T1, T2 relaxation and magnetization transfer in tissue at 3T [J].
Stanisz, GJ ;
Odrobina, EE ;
Pun, J ;
Escaravage, M ;
Graham, SJ ;
Bronskill, MJ ;
Henkelman, RM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) :507-512
[25]   A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients [J].
Tortoriello, TA ;
Stayer, SA ;
Mott, AR ;
McKenzie, ED ;
Fraser, CD ;
Andropoulos, DB ;
Chang, AC .
PEDIATRIC ANESTHESIA, 2005, 15 (06) :495-503
[26]   Jugular venous bulb oxyhemoglobin saturation during cardiac surgery: Accuracy and reliability using a continuous monitor [J].
Trubiano, P ;
Heyer, EJ ;
Adams, DC ;
McMahon, DJ ;
Christiansen, I ;
Rose, EA ;
Delphin, E .
ANESTHESIA AND ANALGESIA, 1996, 82 (05) :964-968
[27]   EARLY JUGULAR BULB OXYGENATION MONITORING IN COMATOSE PATIENTS AFTER AN OUT-OF-HOSPITAL CARDIAC-ARREST [J].
VANDERHOEVEN, JG ;
DEKONING, J ;
COMPIER, EA ;
MEINDERS, AE .
INTENSIVE CARE MEDICINE, 1995, 21 (07) :567-572
[28]   MRI SUSCEPTOMETRY - IMAGE-BASED MEASUREMENT OF ABSOLUTE SUSCEPTIBILITY OF MR CONTRAST AGENTS AND HUMAN BLOOD [J].
WEISSKOFF, RM ;
KIIHNE, S .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (02) :375-383
[29]   Jugular venous bulb oxygen saturation monitoring in arteriovenous malformation surgery [J].
WilderSmith, OHG ;
Fransen, P ;
deTribolet, N ;
Tassonyi, E .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1997, 9 (02) :162-165
[30]   Robust field map generation using a triple-echo acquisition [J].
Windischberger, C ;
Robinson, S ;
Rauscher, A ;
Barth, M ;
Moser, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) :730-734