Single-shot magnetic field mapping embedded in echo-planar time-course imaging

被引:38
作者
Roopchansingh, V [1 ]
Cox, RW [1 ]
Jesmanowicz, A [1 ]
Ward, BD [1 ]
Hyde, JS [1 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
关键词
magnetic field mapping; real time; geometric correction; respiration artifacts; echo-planar;
D O I
10.1002/mrm.10587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A technique for acquiring magnetic field maps simultaneously with gradient-recalled echo-planar time-course data is described. This technique uses a trajectory in which the central part of k-space is collected twice. For a 64 x 64 image acquired with a 125-kHz bandwidth, a field map suitable for geometric correction can be collected simultaneously with the echo-planar time-course data in <70 ms. The field maps generated by this technique are registered with the magnitude images because they are calculated using the same data. They do not suffer from errors due to subject motion, or from different geometric distortions that can result from using different pulse sequences. In addition to correcting geometric distortions that resulted from dynamic magnetic field perturbations, this method was used to measure field shifts arising from respiration and jaw motion across five subjects. Values ranged from 0.035 to 0.165 parts per million (ppm). (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:839 / 843
页数:5
相关论文
共 20 条
[1]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[2]   Magnetic field changes in the human brain due to swallowing or speaking [J].
Birn, RM ;
Bandettini, PA ;
Cox, RW ;
Jesmanowicz, A ;
Shaker, R .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) :55-60
[3]   Simulation of human respiration in fMRI with a mechanical model [J].
Brosch, JR ;
Talavage, TM ;
Ulmer, JL ;
Nyenhuis, JA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) :700-707
[4]   Dynamic shim updating (DSU) for multislice signal acquisition [J].
de Graaf, RA ;
Brown, PB ;
McIntyre, S ;
Rothman, DL ;
Nixon, TW .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :409-416
[5]   Artifact due to Bo fluctuations in fMRI:: Correction using the k-space central line [J].
Durand, E ;
van de Moortele, PF ;
Pachot-Clouard, M ;
Le Bihan, D .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :198-201
[6]  
JESMANOWICZ A, 1997, P ISMRM 5 SCI M VANC, P1983
[7]  
JESMANOWICZ A, 1993, P SMRM 12 ANN M NEW, P1239
[8]  
JESMANOWICZ A, 2001, P 9 ANN M ISMRM GLAS, P617
[9]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[10]  
Nayak KS, 2000, MAGNET RESON MED, V43, P151, DOI 10.1002/(SICI)1522-2594(200001)43:1<151::AID-MRM19>3.0.CO