Evaluation of isopentane, R-245fa and their mixtures as working fluids for organic Rankine cycles

被引:113
作者
Garg, Pardeep [1 ]
Kumar, Pramod [1 ]
Srinivasan, Kandadai [1 ,2 ]
Dutta, Pradip [1 ]
机构
[1] Indian Inst Sci, Dept Mech Engn, Bangalore 560012, Karnataka, India
[2] Univ Melbourne, Dept Mech Engn, Melbourne, Vic 3010, Australia
关键词
Organic Rankine cycles; Hydrocarbons; Refrigerants; Mixtures; Irreversibility; ZEOTROPIC MIXTURES; TEMPERATURE; RECOVERY; SELECTION;
D O I
10.1016/j.applthermaleng.2012.08.056
中图分类号
O414.1 [热力学];
学科分类号
摘要
Low grade thermal energy from sources such as solar, geothermal and industrial waste heat in the temperature range of 380-425 K can be converted to electrical energy with reasonable efficiency using isopentane and R-245fa. While the former is flammable and the latter has considerable global warming potential, their mixture in 0.7/0.3 mole fraction is shown to obviate these disadvantages and yet retain dominant merits of each fluid. A realistic thermodynamic analysis is carried out wherein the possible sources of irreversibilities such as isentropic efficiencies of the expander and the pump and entropy generation in the regenerator, boiler and condenser are accounted for. The performance of the system in the chosen range of heat source temperatures is evaluated. A technique of identifying the required source temperature for a given output of the plant and the maximum operating temperature of the working fluid is developed. This is based on the pinch point occurrence in the boiler and entropy generation in the boiling and superheating regions of the boiler. It is shown that cycle efficiencies of 10-13% can be obtained in the range investigated at an optimal expansion ratio of 7-10. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:292 / 300
页数:9
相关论文
共 23 条
[1]   Comparative energetic analysis of high-temperature subcritical and transcritical Organic Rankine Cycle (ORC). A biomass application in the Sibari district [J].
Algieri, Angelo ;
Morrone, Pietropaolo .
APPLIED THERMAL ENGINEERING, 2012, 36 :236-244
[2]   Effect of dry hydrocarbons and critical point temperature on the efficiencies of organic Rankine cycle [J].
Aljundi, Isam H. .
RENEWABLE ENERGY, 2011, 36 (04) :1196-1202
[3]   Multicomponent working fluids for organic rankine cycles (ORCs) [J].
Angelino, G ;
Di Paliano, PC .
ENERGY, 1998, 23 (06) :449-463
[4]   A review of thermodynamic cycles and working fluids for the conversion of low-grade heat [J].
Chen, Huijuan ;
Goswami, D. Yogi ;
Stefanakos, Elias K. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (09) :3059-3067
[5]  
Curran H.M., 1979, DOECS30202T1
[6]  
Grabinski P., 2011, THESIS U ICELAND
[7]   Zeotropic mixtures as working fluids in Organic Rankine Cycles for low-enthalpy geothermal resources [J].
Heberle, Florian ;
Preissinger, Markus ;
Brueggemann, Dieter .
RENEWABLE ENERGY, 2012, 37 (01) :364-370
[8]   Optimum design criteria for an Organic Rankine cycle using low-temperature geothermal heat sources [J].
Hettiarachchia, H. D. Madhawa ;
Golubovica, Mihajlo ;
Worek, William M. ;
Ikegami, Yasuyuki .
ENERGY, 2007, 32 (09) :1698-1706
[9]   A review of organic Rankine cycles (ORCs) for the recovery of low-grade waste heat [J].
Hung, TC ;
Shai, TY ;
Wang, SK .
ENERGY, 1997, 22 (07) :661-667
[10]   Waste heat recovery of organic Rankine cycle using dry fluids [J].
Hung, TC .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (05) :539-553