Capillary electrochromatography of peptides on microfabricated poly(dimethylsiloxane) chips modified by cerium(IV)-catalyzed polymerization

被引:119
作者
Slentz, BE [1 ]
Penner, NA [1 ]
Regnier, FE [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
electrochromatography; chip technology; peptides; poly(dimethylsiloxane);
D O I
10.1016/S0021-9673(01)01319-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Vinylsulfonic acid, acrylic acid, 2-acrylamido-2-methylpropanesulfonic acid (AMPS), 4-styrenesulfonic acid, and stearyl methacrylate were used for successful modification of the surface of poly(dimethylsiloxane) (PDMS) by cerium(IV) catalyzed polymerization on microfabricated collocated monolith support structures microchips. Reproducible and stable coatings were obtained allowing highly efficient separations of a peptide mixture with RSD for retention times below 2.6%. AMPS-coated PDMS channels were shown to give a reproducible separation of a synthetic peptide mixture for over a month. Subsequent modification of microchip channels by AMPS and methoxydimethyloctadecylsilane allowed selective separation of complex bovine serum albumin digest with high reproducibility, and efficiency of about 620 000 plates/m. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 35 条
[1]   Overview of capillary electrophoresis and capillary electrochromatography [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :443-463
[2]   POLYMER SURFACE FUNCTIONALIZATION AND GRAFTING BY A SIMPLE AND INEXPENSIVE METHOD [J].
BAMFORD, CH ;
ALLAMEE, KG .
MACROMOLECULAR RAPID COMMUNICATIONS, 1994, 15 (04) :379-384
[3]   Electroosmosis- and pressure-driven chromatography in chips using continuous beds [J].
Ericson, C ;
Holm, J ;
Ericson, T ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :81-87
[4]   Packing materials and separation efficiencies in capillary electrochromatography [J].
Fujimoto, C .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (04) :291-301
[5]   Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography [J].
Gusev, I ;
Huang, X ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :273-290
[6]   Capillary electrochromatography of peptides in a microfabricated system [J].
He, B ;
Ji, JY ;
Regnier, FE .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :257-262
[7]   A picoliter-volume mixer for microfluidic analytical systems [J].
He, B ;
Burke, BJ ;
Zhang, X ;
Zhang, R ;
Regnier, FE .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :1942-1947
[8]   Microfabricated liquid chromatography columns based on collocated monolith support structures [J].
He, B ;
Regnier, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :925-932
[9]   Fabrication of nanocolumns for liquid chromatography [J].
He, B ;
Tait, N ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3790-3797
[10]   Standard and capillary chromatography, including electrochromatography, on continuous polymer beds (monoliths), based on water-soluble monomers [J].
Hjertén, S .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (04) :1205-1214