Fast structural brain imaging using an MDEFT sequence with a FLASH-EPI hybrid readout

被引:15
作者
Deichmann, R. [1 ]
机构
[1] Inst Neurol, Wellcome Dept Imaging Neurosci, London WC1N 3BG, England
基金
英国惠康基金;
关键词
D O I
10.1016/j.neuroimage.2006.08.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A sequence for the fast acquisition of T1 weighted structural brain images with whole brain coverage and isotropic resolution of 1 mm is presented. It is based on MDEFT with a FLASH-EPI hybrid readout. Several techniques for artefact suppression are implemented, like echo time shifting, asymmetric k-space sampling, and navigator echo acquisition. It is shown experimentally that the hybrid MDEFT sequence with a total duration of 8 min yields approximately the same signal-to-noise and contrast-to-noise ratios as a 12 min standard MDEFT sequence based on a FLASH readout. Further experiments show that echo time shifting suppresses artefacts in the vicinity of the scalp and in areas suffering from field inhomogeneities and that the concept of asymmetric k-space sampling reduces the susceptibility to head movement. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1066 / 1071
页数:6
相关论文
共 18 条
[1]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[2]   Optimized RF excitation for anatomical brain imaging of the occipital lobe using the 3D MDEFT sequence and a surface transmit coil [J].
Deichmann, R .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1212-1216
[3]   Optimisation of the 3D MDEFT sequence for anatomical brain imaging: Technical implications at 1.5 and 3 T [J].
Deichmann, R ;
Schwarzbauer, C ;
Turner, R .
NEUROIMAGE, 2004, 21 (02) :757-767
[4]   CALCULATION OF SIGNAL INTENSITIES IN HYBRID SEQUENCES FOR FAST NMR IMAGING [J].
DEICHMANN, R ;
ADOLF, H ;
NOTH, U ;
KUCHENBROD, E ;
SCHWARZBAUER, C ;
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :481-489
[5]   RAPID 3-DIMENSIONAL MR IMAGING USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :363-368
[6]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[7]  
Hennel F, 1997, CONCEPT MAGNETIC RES, V9, P43, DOI 10.1002/(SICI)1099-0534(1997)9:1<43::AID-CMR4>3.0.CO
[8]  
2-N
[9]   Signal intensities in FLASH-EPI-Hybrid sequences [J].
Hillenbrand, C ;
Deichmann, R ;
Hahn, D ;
Haase, A .
JOURNAL OF MAGNETIC RESONANCE, 1999, 139 (01) :74-80
[10]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488