Optimisation of the 3D MDEFT sequence for anatomical brain imaging: Technical implications at 1.5 and 3 T

被引:359
作者
Deichmann, R
Schwarzbauer, C
Turner, R
机构
[1] UCL, Wellcome Dept Imaging Neurosci, Neurol Inst, London WC1N 3BG, England
[2] MRC, Cognit & Brain Sci Unit, Cambridge CB2 2EF, England
基金
英国惠康基金;
关键词
anatomical brain imaging; MDEFT sequence; structural brain imaging;
D O I
10.1016/j.neuroimage.2003.09.062
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
An algorithm for the optimisation of 3D Modified Driven Equilibrium Fourier Transform (MDEFT) sequences for T1-weighted anatomical brain imaging is presented. Imaging parameters are optimised for a clinical whole body scanner and a clinical head scanner operating at 1.5 and 3 T, respectively. In vivo studies show that the resulting sequences allow for the whole brain acquisition of anatomical scans with an isotropic resolution of 1 mm and high contrast-to-noise ratio (CNR) in an acceptable scan time of 12 min. Typical problems related to the scanner-specific hardware configurations are discussed in detail, especially the occurrence of flow artefacts in images acquired with head transmit coils and the enhancement of scalp intensities in images acquired with phased array receive coils. It is shown both theoretically and experimentally that these problems can be avoided by using spin tagging and fat saturation. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:757 / 767
页数:11
相关论文
共 24 条
[1]   Multimodal image coregistration and partitioning - A unified framework [J].
Ashburner, J ;
Friston, K .
NEUROIMAGE, 1997, 6 (03) :209-217
[2]  
Berry I, 1999, J MAGN RESON IMAGING, V9, P441, DOI 10.1002/(SICI)1522-2586(199903)9:3<441::AID-JMRI12>3.0.CO
[3]  
2-R
[4]   STRATEGIES TO IMPROVE CONTRAST IN TURBOFLASH IMAGING - REORDERED PHASE ENCODING AND K-SPACE SEGMENTATION [J].
CHIEN, D ;
ATKINSON, DJ ;
EDELMAN, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01) :63-70
[5]   Rapid T1 mapping using multislice echo planar imaging [J].
Clare, S ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :630-634
[6]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[7]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127
[8]   RF inhomogeneity compensation in structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :398-402
[9]   CALCULATION OF SIGNAL INTENSITIES IN HYBRID SEQUENCES FOR FAST NMR IMAGING [J].
DEICHMANN, R ;
ADOLF, H ;
NOTH, U ;
KUCHENBROD, E ;
SCHWARZBAUER, C ;
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :481-489
[10]   RAPID 3-DIMENSIONAL MR IMAGING USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :363-368