Rapid T1 mapping using multislice echo planar imaging

被引:106
作者
Clare, S [1 ]
Jezzard, P [1 ]
机构
[1] Univ Oxford, Dept Clin Neurol, Ctr Funct Magnet Resonance Imaging Brain, Oxford, England
关键词
T-1; EPI; quantitative MRI; white matter disease; high-field MRI; relaxation times; brain;
D O I
10.1002/mrm.1085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Determination of neurological pathology in white matter disease can be made in a semiquantitative way from T-1- or T-2-weighted images. A higher level of quantification based on measured T-1 or T-2 values has been either limited to specific regions of interest or to low-resolution maps. Higher-resolution T-1 maps have proved difficult to obtain due to the excessively long scan times required using conventional techniques, In this study, clinically acceptable images are obtained by using single-shot echo planar imaging (EPI) with an acquisition scheme that maximizes signal-to-noise while minimizing the scan time. Magn Reson Med 45:630-634, 2001, (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:630 / 634
页数:5
相关论文
共 26 条
[1]   PRECISION IN CALCULATED-RHO, T1 AND T2 IMAGES AS A FUNCTION OF DATA-ANALYSIS METHOD [J].
BAKKER, CJG ;
DEGRAAF, CN .
MAGNETIC RESONANCE IMAGING, 1988, 6 (01) :3-8
[2]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[3]   REPRODUCIBILITY OF RELAXATION AND SPIN-DENSITY PARAMETERS IN PHANTOMS AND THE HUMAN-BRAIN MEASURED BY MR IMAGING AT 1.5-T [J].
BREGER, RK ;
WEHRLI, FW ;
CHARLES, HC ;
MACFALL, JR ;
HAUGHTON, VM .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) :649-662
[4]   Ghost artifact reduction for echo planar imaging using image phase correction [J].
Buonocore, MH ;
Gao, LS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :89-100
[5]   A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :23-34
[6]  
Deichmann R, 1999, MAGNET RESON MED, V42, P206, DOI 10.1002/(SICI)1522-2594(199907)42:1<206::AID-MRM28>3.0.CO
[7]  
2-Q
[8]  
GLARE S, 1999, INT SOC MAGNETIC RES, P1976
[9]   ACCURATE MEASUREMENT OF T(1) IN-VIVO IN LESS-THAN 3 SECONDS USING ECHO-PLANAR IMAGING [J].
GOWLAND, P ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :351-354
[10]   A SIMPLE METHOD FOR THE RESTORATION OF SIGNAL POLARITY IN MULTIIMAGE INVERSION RECOVERY SEQUENCES FOR MEASURING T1 [J].
GOWLAND, PA ;
LEACH, MO .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) :224-231