RF inhomogeneity compensation in structural brain imaging

被引:57
作者
Deichmann, R [1 ]
Good, CD [1 ]
Turner, R [1 ]
机构
[1] Inst Neurol, Wellcome Dept Cognit Neurol, London WC1N 3BG, England
关键词
structural imaging; MP-RAGE; RF pulse; RF inhomogeneity; anatomical imaging;
D O I
10.1002/mrm.10050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional T-1-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with centric phase encoding (PE) in the inner loop provide structural brain images with a high spatial resolution and high tissue contrast. A disadvantage of this sequence type is the susceptibility to inhomogeneities of the radiofrequency (RF) coil, which may result in poor image contrast in some peripheral regions. A special excitation pulse is presented which compensates for these effects in both the head/foot and anterior/posterior directions. This pulse has a duration of only 1.3 ms and is thus compatible with the short repetition times (TRs) required for MP-RAGE imaging. It is shown experimentally that images acquired with the compensation pulse may be segmented without using intensity correction algorithms during data postprocessing. Magn Reson Med 47:398-402, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:398 / 402
页数:5
相关论文
共 15 条
[1]   Multimodal image coregistration and partitioning - A unified framework [J].
Ashburner, J ;
Friston, K .
NEUROIMAGE, 1997, 6 (03) :209-217
[2]   CENTRIC PHASE-ENCODING ORDER IN 3-DIMENSIONAL MP-RAGE SEQUENCES - APPLICATION TO ABDOMINAL IMAGING [J].
BAMPTON, AEH ;
RIEDERER, SJ ;
KORIN, HW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :327-334
[3]   A comparison of magnetization prepared 3D gradient-echo (MP-RAGE) sequences for imaging of intracranial lesions [J].
Bluml, S ;
Schad, LR ;
Scharf, J ;
Wenz, F ;
Knopp, MV ;
Lorenz, WJ .
MAGNETIC RESONANCE IMAGING, 1996, 14 (03) :329-335
[4]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127
[5]   OPTIMIZATION OF PARAMETER VALUES FOR COMPLEX PULSE SEQUENCES BY SIMULATED ANNEALING - APPLICATION TO 3D MP-RAGE IMAGING OF THE BRAIN [J].
EPSTEIN, FH ;
MUGLER, JP ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) :164-177
[6]  
EPSTEIN FH, 1995, J MAGN RESON IMAGING, V4, P463
[7]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[8]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[9]   SHAPING THE SIGNAL RESPONSE DURING THE APPROACH TO STEADY-STATE IN 3-DIMENSIONAL MAGNETIZATION-PREPARED RAPID GRADIENT-ECHO IMAGING USING VARIABLE FLIP ANGLES [J].
MUGLER, JP ;
EPSTEIN, FH ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :165-185
[10]   RAPID 3-DIMENSIONAL T1-WEIGHTED MR IMAGING WITH THE MP-RAGE SEQUENCE [J].
MUGLER, JP ;
BROOKEMAN, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :561-567