Realtime PCR Is More Sensitive than Multiplex PCR for Diagnosis and Serotyping in Children with Culture Negative Pneumococcal Invasive Disease

被引:107
作者
Azzari, Chiara [1 ]
Moriondo, Maria
Indolfi, Giuseppe
Cortimiglia, Martina
Canessa, Clementina
Becciolini, Laura
Lippi, Francesca
de Martino, Maurizio
Resti, Massimo
机构
[1] Anna Meyer Childrens Hosp, Dept Pediat, Florence, Italy
来源
PLOS ONE | 2010年 / 5卷 / 02期
关键词
STREPTOCOCCUS-PNEUMONIAE; TIME PCR; CAPSULAR SEROTYPES; SURVEILLANCE; IDENTIFICATION; MENINGITIS; VACCINE; SAMPLES;
D O I
10.1371/journal.pone.0009282
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Pneumococcal serotyping is usually performed by Quellung reaction, considered the gold standard test. However the method cannot be used on culture-negative samples. Molecular methods can be a useful alternative. The aim of the study was to evaluate the use of Multiplex-sequential-PCR (MS-PCR) or Realtime-PCR on blood samples for diagnosis and serotyping of invasive pneumococcal disease (IPD) in a pediatric clinical setting. Methodology/Principal Findings: Sensitivity and specificity of MS-PCR and Realtime-PCR have been evaluated both on 46 well characterized pneumococcal isolates and on 67 clinical samples from children with culture-negative IPD. No difference in sensitivity and specificity between MS-PCR and Realtime PCR was found when the methods were used on isolates: both methods could type 100% isolates and the results were always consistent with culture-based methods. On the contrary, when used on clinical samples 43/67 (64.2%) were typeable by MS-PCR and 61/67 (91.0%) by Realtime-PCR (p = 0.0004, K Cohen 0.3, McNemar's p<0.001). Non-typeability by MS-PCR was associated in 18/20 cases (90.0%) with low bacterial load. The difference between the two methods was present both when they were used on normally sterile fluids (respectively 31/33 (93.9%) typeable samples for Realtime-PCR and 24/33 (72.7%) for MS-PCR, p = 0.047, 95% CL 0.03-0.98; K Cohen 0.3; McNemar's p = 0.0016) and when they were used on nasopharyngeal swabs (respectively 30/34 (88.2%) typeable samples for Realtime-PCR and 19/34 (55.9%) for MS-PCR, p = 0.007, 95% CL 0.04-0.66); the presence of multiple pneumococcal serotypes in nasopharyngeal swabs was found more frequently by Realtime PCR (19/30; 63.3%) than by Multiplex-sequential PCR (3/19; 15.8%; p = 0.003; 95% CL 1.87-39.97). Conclusions/Significance: In conclusion, both MS-PCR and Realtime PCR can be used for pneumococcal serotyping of most serotypes/serogroups directly on clinical samples from culture-negative patients but Realtime-PCR appears more sensitive.
引用
收藏
页数:7
相关论文
共 39 条
[1]   Use of antiserum-coated latex particles for serotyping Streptococcus pneumoniae [J].
Arai, S ;
Konda, T ;
Wada, A ;
Matsunaga, Y ;
Okabe, N ;
Watanabe, H ;
Inouye, S .
MICROBIOLOGY AND IMMUNOLOGY, 2001, 45 (02) :159-162
[2]   Molecular detection methods and serotyping performed directly on clinical samples improve diagnostic sensitivity and reveal increased incidence of invasive disease by Streptococcus pneumoniae in Italian children [J].
Azzari, Chiara ;
Moriondo, Maria ;
Indolfi, Giuseppe ;
Massai, Cristina ;
Becciolini, Laura ;
de Martino, Maurizio ;
Resti, Massimo .
JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 57 (10) :1205-1212
[3]   Reduction of carriage and transmission of Streptococcus pneumoniae:: The beneficial "Side effect" of pneumococcal conjugate vaccine [J].
Azzari, Chiara ;
Resti, Massimo .
CLINICAL INFECTIOUS DISEASES, 2008, 47 (08) :997-999
[4]   Streptococcus pneumoniae:: Description of the pathogen, disease epidemiology, treatment, and prevention [J].
Bridy-Pappas, AE ;
Margolis, MB ;
Center, KJ ;
Isaacman, DJ .
PHARMACOTHERAPY, 2005, 25 (09) :1193-1212
[5]   Detection of Streptococcus pneumoniae Strain Cocolonization in the Nasopharynx [J].
Brugger, Silvio D. ;
Hathaway, Lucy J. ;
Muehlemann, Kathrin .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) :1750-1756
[6]   SEROTYPE DISTRIBUTION OF STREPTOCOCCUS-PNEUMONIAE INFECTIONS AMONG PRESCHOOL-CHILDREN IN THE UNITED-STATES, 1978-1994 - IMPLICATIONS FOR DEVELOPMENT OF A CONJUGATE VACCINE [J].
BUTLER, JC ;
BREIMAN, RF ;
LIPMAN, HB ;
HOFMANN, J ;
FACKLAM, RR .
JOURNAL OF INFECTIOUS DISEASES, 1995, 171 (04) :885-889
[7]   Temporal trends of invasive disease due to Streptococcus pneumoniae among children in the Intermountain West:: Emergence of nonvaccine serogroups [J].
Byington, CL ;
Samore, MH ;
Stoddard, GJ ;
Barlow, S ;
Daly, J ;
Korgenski, K ;
Firth, S ;
Glover, D ;
Jensen, J ;
Mason, EO ;
Shutt, CK ;
Pavia, AT .
CLINICAL INFECTIOUS DISEASES, 2005, 41 (01) :21-29
[8]   Evaluation and improvement of real-time PCR assays targeting lytA, ply, and psaA genes for detection of pneumococcal DNA [J].
Carvalho, Maria da Gloria S. ;
Tondella, Maria Lucia ;
McCaustland, Karen ;
Weidlich, Luciana ;
McGee, Lesley ;
Mayer, Leonard W. ;
Steigerwalt, Arnold ;
Whaley, Melissa ;
Facklam, Richard R. ;
Fields, Barry ;
Carlone, George ;
Ades, Edwin W. ;
Dagan, Ron ;
Sampson, Jacquelyn S. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (08) :2460-2466
[9]   How valid is single-colony isolation for surveillance of Streptococcus pneumoniae carriage? [J].
Charalambous, B. M. ;
Oriyo, Ndekya M. ;
Gillespie, S. H. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (07) :2467-2468
[10]   Simultaneous detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae in suspected cases of meningitis and septicemia using real-time PCR [J].
Corless, CE ;
Guiver, M ;
Borrow, R ;
Edwards-Jones, V ;
Fox, AJ ;
Kaczmarski, EB .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (04) :1553-1558