The BIGTT Test -: A novel test for simultaneous measurement of pancreatic β-cell function, insulin sensitivity, and glucose tolerance

被引:94
作者
Hansen, Torben
Drivsholm, Thomas
Urhammer, Soren A.
Palacios, Rene T.
Volund, Aage
Borch-Johnsen, Knut
Pedersen, Oluf
机构
[1] Steno Diabet Ctr, DK-2820 Gentofte, Denmark
[2] Glostrup Univ Hosp, Res Ctr Prevent & Hlth, Glostrup, Denmark
[3] Novo Nordisk AS, Dept Biostat, Copenhagen, Denmark
关键词
D O I
10.2337/dc06-1240
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
OBJECTIVE-Insulin resistance and impaired P-cell function are key elements in the pathogenesis of type 2 diabetes. We aimed to develop valid algorithms for estimation of the insulin sensitivity index (S,) and acute insulin response (AIR) derived from simple and cheap physiological measurements that could be used in large-scale metabolic, genetic, and epidemiological studies. RESEARCH DESIGN AND METHODS-For our purpose, data from an oral glucose tolerance test (OGTT) (18 samples during 240 min) and a tolbutamide-modified intravenous glucose tolerance test (IVGTT) (33 samples during 180 min) from 258 individuals with fasting plasma glucose < 7 mmol/l and 2-h plasma glucose < 7.8 mmol/l were used for model development and internal validation. Data from an additional 28 individuals were used for external validation. Bergman's minimal model was used to calculate S-1, and the trapezoidal method was used to calculate AIR(0-8) (min). Multiple linear regression was applied to derive predictive equations of log(S-1) and log(AIR(0-8 min)) using data on sex, BMI, plasma glucose, and serum insulin levels obtained during the OGTT. RESULTS-We demonstrate that it is possible to obtain estimates of S-1 (BIGTT-S-1) and AIR (BIGTT-AIR) that are highly correlated to IVGTT-derived values of S-1 (R-2 = 0.77) and AIR (R-2 = 0.54). In the two validation datasets we obtained similar results. CONCLUSIONS-Data from OGTTs can provide accurate measures of insulin sensitivity and P-cell function, which can be used in large scale metabolic, genetic, and epidemiological studies.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 27 条
[21]
Insulin sensitivity indices obtained from oral glucose tolerance testing - Comparison with the euglycemic insulin clamp [J].
Matsuda, M ;
DeFronzo, RA .
DIABETES CARE, 1999, 22 (09) :1462-1470
[22]
HOMEOSTASIS MODEL ASSESSMENT - INSULIN RESISTANCE AND BETA-CELL FUNCTION FROM FASTING PLASMA-GLUCOSE AND INSULIN CONCENTRATIONS IN MAN [J].
MATTHEWS, DR ;
HOSKER, JP ;
RUDENSKI, AS ;
NAYLOR, BA ;
TREACHER, DF ;
TURNER, RC .
DIABETOLOGIA, 1985, 28 (07) :412-419
[23]
MINMOD - A COMPUTER-PROGRAM TO CALCULATE INSULIN SENSITIVITY AND PANCREATIC RESPONSIVITY FROM THE FREQUENTLY SAMPLED INTRAVENOUS GLUCOSE-TOLERANCE TEST [J].
PACINI, G ;
BERGMAN, RN .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1986, 23 (02) :113-122
[24]
UNDERSTANDING ORAL GLUCOSE-TOLERANCE - COMPARISON OF GLUCOSE OR INSULIN MEASUREMENTS DURING THE ORAL GLUCOSE-TOLERANCE TEST WITH SPECIFIC MEASUREMENTS OF INSULIN-RESISTANCE AND INSULIN-SECRETION [J].
PHILLIPS, DIW ;
CLARK, PM ;
HALES, CN ;
OSMOND, C .
DIABETIC MEDICINE, 1994, 11 (03) :286-292
[25]
Report of the American Diabetes Association's task force on standardization of the insulin assay [J].
Robbins, DC ;
Andersen, L ;
Bowsher, R ;
Chance, R ;
Dinesen, B ;
Frank, B ;
Gingerich, R ;
Goldstein, D ;
Widemeyer, HM ;
Haffner, S ;
Hales, CN ;
Jarett, L ;
Polonsky, K ;
Porte, D ;
Skyler, J ;
Webb, G ;
Gallagher, K .
DIABETES, 1996, 45 (02) :242-256
[26]
Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity [J].
Stumvoll, M ;
Mitrakou, A ;
Pimenta, W ;
Jenssen, T ;
Yki-Járvinen, H ;
Van Haeften, T ;
Renn, W ;
Gerich, J .
DIABETES CARE, 2000, 23 (03) :295-301
[27]
Wareham N J, 1995, Diabet Med, V12, P931