Effect of filler content on mechanical and dynamic mechanical properties of particulate biphasic calcium phosphate-polylactide composites

被引:242
作者
Bleach, NC
Nazhat, SN
Tanner, KE
Kellomäki, M
Törmälä, P
机构
[1] Queen Mary Univ London, IRC Biomed Mat, London E1 4NS, England
[2] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
基金
英国工程与自然科学研究理事会;
关键词
polylactide; biphasic calcium phosphate; bioabsorbable composite; mechanical properties; dynamic mechanical analysis; glass transition temperature;
D O I
10.1016/S0142-9612(01)00283-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A bioabsorbable self-reinforced polylactide/biphasic calcium phosphate (BCP) composite is being developed for fracture fixation plates. One manufacturing route is to produce preimpregnated sheets by pulling polylactide (PLA) fibres through a suspension of BCP filler in a PLA solution and compression moulding the prepreg to the desired shape. To aid understanding of the process, interactions between the matrix and filler were investigated. Composite films containing 0 0.25 volume fraction filler, produced by solvent casting, were analysed using SEM, tensile testing and dynamic mechanical analysis (DMA). Homogeneous films could be made, although some particle agglomeration was seen at higher filler volume fractions. As the filler content increased, the failure strain decreased due to a reduction in the amount of ductile polymer present and the ultimate tensile strength (UTS) decreased because of agglomeration and void formation at higher filler content. The matrix glass transition temperature increased due to polymer chain adsorption and immobilization onto the BCP particles. Complex damping mechanisms, such as particle-particle agglomeration, may exist at the higher BCP volume fractions. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:1579 / 1585
页数:7
相关论文
共 30 条
[1]  
Brandrup J., 1999, Polymer handbook, VII
[2]   MECHANICAL AND THERMAL-EXPANSION PROPERTIES OF A PARTICULATE FILLED POLYMER [J].
BRASSELL, GW ;
WISCHMANN, KB .
JOURNAL OF MATERIALS SCIENCE, 1974, 9 (02) :307-314
[3]   FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324
[4]  
CLAES L E, 1992, Clinical Materials, V10, P41, DOI 10.1016/0267-6605(92)90083-6
[5]   Resorbable continuous-fibre reinforced polymers for osteosynthesis [J].
Dauner, M ;
Planck, H ;
Caramaro, L ;
Missirlis, Y ;
Panagiotopoulos, E .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (03) :173-179
[6]  
FERRIGNO TH, 1987, HDB FILLERS PLASTICS, P38
[7]   Biodegradable polylactide plates and screws in orthognathic surgery: technical note [J].
Haers, PE ;
Suuronen, R ;
Lindqvist, C ;
Sailer, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (02) :87-91
[8]   Reinforcement of biodegradable poly(ester-urethane) with fillers [J].
Hiljanen-Vainio, M ;
Heino, M ;
Seppala, JV .
POLYMER, 1998, 39 (04) :865-872
[9]   Preparation and mechanical properties of polylactic acid composites containing hydroxyapatite fibers [J].
Kasuga, T ;
Ota, Y ;
Nogami, M ;
Abe, Y .
BIOMATERIALS, 2001, 22 (01) :19-23
[10]  
KELLOMAKI M, 1997, 13 EUR C BIOM SWED 4, P90