Standardization of multiple spirometers at widely separated times and places

被引:23
作者
Linn, WS [1 ]
Solomon, JC [1 ]
Gong, H [1 ]
Avol, EL [1 ]
Navidi, WC [1 ]
Peters, JM [1 ]
机构
[1] UNIV SO CALIF, SCH MED, LOS ANGELES, CA USA
关键词
D O I
10.1164/ajrccm.153.4.8616559
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We designed a system for a multiyear longitudinal study of lung function in 12 widely separated communities, intending to minimize variation in instrument-related data. We used multiple rolling-seal spirometer/personal computer systems. Calibrations were checked before, during, and after each day's field testing, using multiple calibration syringes with electronic readouts. The syringes were rotated to obtain data for each syringe-spirometer combination. Before and after each annual field testing season, a laboratory reference spirometer system was calibrated against a water-displacement device and an electronic frequency counter, and then compared against each field spirometer and syringe. Field equipment consistently met American Thoracic Society (ATS) specifications. Variance among spirometers exceeded variance among syringes. A spirometer occasionally changed its volume readout by approximate to 1 to 2%. More rarely, a syringe changed its delivered volume by approximate to 1%. Syringes' electronic readouts tracked changes in delivered volume. Syringe readouts were the most stable component of the system, and were more reproducible than the laboratory water-displacement calibration. We conclude that variation in spirometers may limit the reliability of epidemiologic findings, even when these spirometers meet ATS specifications. Frequent calibration checks traceable to an independent standard, and adjustment of individual test results, can reduce measurement error.
引用
收藏
页码:1309 / 1313
页数:5
相关论文
共 9 条
  • [1] [Anonymous], 1987, Am Rev Respir Dis, V136, P1285
  • [2] CUNNINGHAM J, 1991, CHILDRENS HLTH STUDY
  • [3] ENRIGHT PL, 1987, OFFICE SPIROMETRY, P141
  • [4] VARIABILITY OF FVC AND FEV(1) DUE TO TECHNICIAN, TEAM, DEVICE AND SUBJECT IN AN 8-CENTER STUDY - 3 QUALITY-CONTROL STUDIES IN SAPALDIA
    KUNZLI, N
    ACKERMANNLIEBRICH, U
    KELLER, R
    PERRUCHOUD, AP
    SCHINDLER, C
    LEUENBERGER, P
    ALEAN, P
    BLASER, K
    BOLOGNINI, G
    BONGARD, JP
    BRAENDLI, O
    BRAUN, P
    BRON, C
    BRUTSCHE, M
    DEFILA, C
    DOMENIGHETTI, G
    ELSASSER, S
    FILLIGER, P
    GRIZE, L
    GULDIMANN, P
    HUFSCHMIED, P
    KARRER, W
    KELLERWOSSIDLO, H
    KUNZLI, N
    LUTHI, JC
    MARTIN, BW
    MEDICI, T
    MONN, C
    PEETERS, AG
    PERRUCHOUD, AP
    RADAELLI, A
    SCHWARTZ, J
    SOLARI, G
    SCHOENI, M
    TSCHOPP, JM
    VILLIGER, B
    WUETHRICH, B
    ZELLWEGER, JP
    ZEMP, E
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (03) : 371 - 376
  • [5] LINN WS, 1990, TOTAL EXPOSURE ASSES, P565
  • [6] PERFORMANCE EVALUATION OF CONTEMPORARY SPIROMETERS
    NELSON, SB
    GARDNER, RM
    CRAPO, RO
    JENSEN, RL
    [J]. CHEST, 1990, 97 (02) : 288 - 297
  • [7] LUNG-VOLUMES AND FORCED VENTILATORY FLOWS - REPORT WORKING PARTY STANDARDIZATION OF LUNG-FUNCTION TESTS EUROPEAN-COMMUNITY FOR STEEL AND COAL - OFFICIAL STATEMENT OF THE EUROPEAN RESPIRATORY SOCIETY
    QUANJER, PH
    TAMMELING, GJ
    COTES, JE
    PEDERSEN, OF
    PESLIN, R
    YERNAULT, JC
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1993, 6 : 5 - 40
  • [8] MORTALITY ASSOCIATED WITH RESPIRATORY-FUNCTION AND SYMPTOMS IN ADVANCED AGE - THE FRAMINGHAM-STUDY
    SORLIE, PD
    KANNEL, WB
    OCONNOR, G
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (02): : 379 - 384