Peritrochanteric fractures treated with the Fixion expandable proximal femoral nail: technical note and report of early results

被引:53
作者
Folman, Y [1 ]
Ron, N
Shabat, S
Hopp, M
Sternberg, E
机构
[1] Hillel Yaffe MC, Dept Orthopaed B, IL-38100 Hadera, Israel
[2] Rudolf Elle Hosp, Dept Surg, Eisenberg, Germany
[3] Sorasky MC, Dept Orthopaed B, Tel Aviv, Israel
关键词
hip fracture; intertrochanteric; percutaneous; intramedullary nail;
D O I
10.1007/s00402-006-0110-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The theoretical advantages of intramedullary fixation for peritrochanteric fractures were lessened in practice by implant-related operative problems and postoperative complication. Materials and methods: Forty-nine patients were treated with a newly designed expandable proximal femoral nail (EPFN) and followed thereafter for a minimum of 6 months. Results: After experience was gained in carrying out the procedure, its mean duration was limited to 43.4 +/- 20.2 min and total mean fluoroscopy time to 39.8 +/- 16.1 s. Due to minimal extent of soft tissue trauma blood loss was negligible and rate of postoperative infections reduced. Condensation of cancellous bone in the femoral head as an alternative to reaming and the blunt cone-shaped head of the peg reduced the frequency of head peg cut-out. Homogenic load distribution along the nail interface decreased the concentration of stress and thereby eliminated the risk of postoperative femoral fracture distal to the implant stem. Conclusion: The EPFN may be considered as a further evolution of implants designed to stabilize peritrochanteric fractures of all grades.
引用
收藏
页码:211 / 214
页数:4
相关论文
共 26 条
[1]
Ahrengart L, 2002, CLIN ORTHOP RELAT R, P209
[2]
BANNISTER GC, 1990, CLIN ORTHOP RELAT R, P242
[3]
Baumgaertner MR, 1998, CLIN ORTHOP RELAT R, P87
[4]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[5]
FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[6]
CLAWSON D K, 1964, J Trauma, V4, P737, DOI 10.1097/00005373-196411000-00001
[7]
DAVIS J, 1991, ORTHOPEDICS, V14, P939
[8]
THE GAMMA-NAIL FOR PERITROCHANTERIC FRACTURES [J].
HALDER, SC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :340-344
[9]
Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures - A prospective, randomized study of one hundred patients [J].
Hardy, DCR ;
Descamps, PY ;
Krallis, P ;
Fabeck, L ;
Smets, P ;
Bertens, CL ;
Delince, PE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :618-630
[10]
Intertrochanteric fractures of the femur: A randomized prospective comparison of the gamma nail and the Ambi hip screw [J].
Hoffman, CW ;
Lynskey, TG .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1996, 66 (03) :151-155