Articular cartilage volume in the knee: Semiautomated determination from three-dimensional reformations of MR images

被引:102
作者
Piplani, MA
Disler, DG
McCauley, TR
Holmes, TJ
Cousins, JP
机构
[1] ALBANY MED COLL,DEPT RADIOL,ALBANY,NY 12208
[2] RENSSELAER POLYTECH INST,DEPT BIOMED ENGN,IMAGE PROC LAB,TROY,NY
关键词
knee; ligaments; menisci; and cartilage; magnetic resonance (MR); fat suppression; three-dimensional;
D O I
10.1148/radiology.198.3.8628883
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the accuracy of semiautomated quantification of articular cartilage volume from three-dimensional (3D) reformations of magnetic resonance (MR) images. MATERIALS AND METHODS: Sagittal, fat-suppressed, 3D, spoiled gradient-recalled-echo MR imaging of two bovine and two human cadaver knees was performed. Articular cartilage volume was calculated from 3D reformations of the MR images by using a semi-automated program written at the authors' institution. Calculated volumes were compared with directly measured volumes of the surgically removed articular cartilage. RESULTS: The percentage of error of the MR imaging-determined volumes was 6.53% +/- 4.75 (mean +/- standard deviation). A strong correlation between the two sets of observations was shown (r = .997). Linear regression showed the calculated volumes to be highly accurate (slope = 1.002, P >.25). Repeated reformations yielded volumes that were reproducible (mean absolute error, 0.013 mt +/- 0.019) and not significantly different from the measured volume (P >.10). CONCLUSION: Semiautomated quantification of knee articular cartilage from MR images yields highly accurate cartilage volumes.
引用
收藏
页码:855 / 859
页数:5
相关论文
共 14 条
[1]  
BEYAR RB, 1980, CIRCULATION, V81, P297
[2]  
COUSINS JP, 1994, 1994 P SOC MAGN RES, V2, P868
[3]   ACCURACY OF VOLUME MEASUREMENTS OF COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING PHANTOMS BY 3-DIMENSIONAL RECONSTRUCTION AND PRELIMINARY CLINICAL-APPLICATION [J].
DISLER, DG ;
MARR, DS ;
ROSENTHAL, DI .
INVESTIGATIVE RADIOLOGY, 1994, 29 (08) :739-745
[4]   FAT-SUPPRESSED SPOILED GRASS IMAGING OF KNEE HYALINE CARTILAGE - TECHNIQUE OPTIMIZATION AND COMPARISON WITH CONVENTIONAL MR-IMAGING [J].
DISLER, DG ;
PETERS, TL ;
MUSCOREIL, SJ ;
RATNER, LM ;
WAGLE, WA ;
COUSINS, JP ;
RIFKIN, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :887-892
[5]   VOLUMETRIC RENDERING TECHNIQUES - APPLICATIONS FOR 3-DIMENSIONAL IMAGING OF THE HIP [J].
FISHMAN, EK ;
DREBIN, B ;
MAGID, D ;
SCOTT, WW ;
NEY, DR ;
BROOKER, AF ;
RILEY, LH ;
STVILLE, JA ;
ZERHOUNI, EA ;
SIEGELMAN, SS .
RADIOLOGY, 1987, 163 (03) :737-738
[6]   DISPLAY OF 3-DIMENSIONAL INFORMATION IN COMPUTED TOMOGRAPHY [J].
HERMAN, GT ;
LIU, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :155-160
[7]   TEMPORAL-LOBE SEIZURES - LATERALIZATION WITH MR VOLUME MEASUREMENTS OF THE HIPPOCAMPAL-FORMATION [J].
JACK, CR ;
SHARBROUGH, FW ;
TWOMEY, CK ;
CASCINO, GD ;
HIRSCHORN, KA ;
MARSH, WR ;
ZINSMEISTER, AR ;
SCHEITHAUER, B .
RADIOLOGY, 1990, 175 (02) :423-429
[8]   ANALYSIS OF BRAIN AND CEREBROSPINAL-FLUID VOLUMES WITH MR IMAGING .1. METHODS, RELIABILITY, AND VALIDATION [J].
KOHN, MI ;
TANNA, NK ;
HERMAN, GT ;
RESNICK, SM ;
MOZLEY, PD ;
GUR, RE ;
ALAVI, A ;
ZIMMERMAN, RA ;
GUR, RC .
RADIOLOGY, 1991, 178 (01) :115-122
[9]   PERSPECTIVE - 3-DIMENSIONAL IMAGING OF THE MUSCULOSKELETAL SYSTEM [J].
PATE, D ;
RESNICK, D ;
ANDRE, M ;
SARTORIS, DJ ;
KURSUNOGLU, S ;
BIELECKI, D ;
DEV, P ;
VASSILIADIS, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (03) :545-551
[10]   QUANTIFICATION OF ARTICULAR-CARTILAGE IN THE KNEE WITH PULSED SATURATION-TRANSFER SUBTRACTION AND FAT-SUPPRESSED MR-IMAGING - OPTIMIZATION AND VALIDATION [J].
PETERFY, CG ;
VANDIJKE, CF ;
JANZEN, DL ;
GLUER, CC ;
NAMBA, R ;
MAJUMDAR, S ;
LANG, P ;
GENANT, HK .
RADIOLOGY, 1994, 192 (02) :485-491