Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies

被引:8
作者
Korosoglou, G [1 ]
Hansen, A [1 ]
Bekeredjian, R [1 ]
Filusch, A [1 ]
Hardt, S [1 ]
Wolf, D [1 ]
Schellberg, D [1 ]
Katus, HA [1 ]
Kuecherer, H [1 ]
机构
[1] Heidelberg Univ, Dept Cardiol, D-69120 Heidelberg, Germany
关键词
D O I
10.1136/hrt.2005.064246
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate whether myocardial parametric imaging ( MPI) is superior to visual assessment for the evaluation of myocardial viability. Methods and results: Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by ( 1) visual analysis of myocardial opacification; ( 2) quantitative estimation of myocardial blood flow in regions of interest; and ( 3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r(2) = 0.92 versus r(2) = 0.56) and had a lower intraobserver variability (4% v 15%, p< 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p< 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p, 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p< 0.05). Conclusion: MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.
引用
收藏
页码:350 / 356
页数:7
相关论文
共 26 条
[21]   AN ASSOCIATION BETWEEN COLLATERAL BLOOD-FLOW AND MYOCARDIAL VIABILITY IN PATIENTS WITH RECENT MYOCARDIAL-INFARCTION [J].
SABIA, PJ ;
POWERS, ER ;
RAGOSTA, M ;
SAREMBOCK, IJ ;
BURWELL, LR ;
KAUL, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (26) :1825-1831
[22]  
Schiller N B, 1989, J Am Soc Echocardiogr, V2, P358
[23]   Echoscintigraphy: A new imaging modality for the reduction of color blooming and acoustic shadowing in contrast sonography [J].
Schlosser, T ;
Pohl, C ;
Kuntz-Hehner, S ;
Omran, H ;
Becher, H ;
Tiemann, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (07) :985-991
[24]   Identification of hibernating myocardium with quantitative intravenous myocardial contrast echocardiography - Comparison with dobutamine echocardiography and thallium-201 scintigraphy [J].
Shimoni, S ;
Frangogiannis, NG ;
Aggeli, CJ ;
Shan, K ;
Verani, MS ;
Quinones, MA ;
Espada, R ;
Letsou, GV ;
Lawrie, GM ;
Winters, WL ;
Reardon, MJ ;
Zoghbi, WA .
CIRCULATION, 2003, 107 (04) :538-544
[25]  
Wei K, 1998, CIRCULATION, V97, P473
[26]   Incremental value of parametric quantitative assessment of myocardial perfusion by triggered low-power myocardial contrast echocardiography [J].
Yu, EHC ;
Skyba, DM ;
Leong-Poi, H ;
Sloggett, C ;
Jamorski, M ;
Garg, R ;
Iwanochko, RM ;
Siu, SC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (10) :1807-1813