Reversibility of artifacts of fluid volume measurements by bioimpedance caused by position changes during dialysis

被引:8
作者
Fenech, M [1 ]
Jaffrin, MY [1 ]
Malmen, U [1 ]
机构
[1] Univ Technol Compiegne, Dept Biol Engn, Compiegne, France
关键词
bioimpedance spectroscopy; hemodialysis; extracellular fluid monitoring;
D O I
10.1177/039139880202500308
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The effect of temporary position changes, sitting up from supine, on extracellular (ECW) and intracellular (ICW) resistances and fluid volumes calculated from whole body bioimpedance using a Xitron 4200 impedancemeter was investigated on 8 patients during dialysis for a total of 11 tests. It was found that ECW resistance decreased instantaneously by an average of 2.3% when the patient sits up, due to plasma and interstitial fluid shift into the legs which decreases leg resistance, the major contributor to total resistance. This drop in resistance is incorrectly interpreted by the device as an increase in ECW volume which averages 235 ml. But this effect is completely reversible and both ECW resistance and fluid volume rapidly resume their normal course when the patient returns to his initial position. No significant variation in ICW resistance was observed in any of the patients at the position change. We conclude that segmental impedance, which has been proposed to minimize this artifact, is not advisable in dialysis monitoring and that it is simpler to ignore or switch off measurements during the position change so that later data are not affected by it.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 14 条
[1]
Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558
[2]
MEASUREMENT OF TRANS-CELLULAR FLUID SHIFT DURING HEMODIALYSIS .2. INVITRO AND CLINICAL-EVALUATION [J].
DEVRIES, PMJM ;
MEIJER, JH ;
VLAANDEREN, K ;
VISSER, V ;
OE, PL ;
DONKER, AJM ;
SCHNEIDER, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (02) :152-158
[3]
Fluid volumes determination by impedance spectroscopy and hematocrit monitoring: Application to pediatric hemodialysis [J].
Fenech, M ;
Maasrani, M ;
Jaffrin, MY .
ARTIFICIAL ORGANS, 2001, 25 (02) :89-98
[4]
Hanai T., 1968, EMULSION SCI
[5]
JABARA AE, 1995, ASAIO J, V41, pM682, DOI 10.1097/00002480-199507000-00098
[6]
Extracellular and intracellular fluid volume monitoring during dialysis by multifrequency impedancemetry [J].
Jaffrin, MY ;
Maasrani, M ;
Boudailliez, B ;
LeGourrier, A .
ASAIO JOURNAL, 1996, 42 (05) :M533-M538
[7]
VALIDATION OF BIOELECTRICAL-IMPEDANCE MEASUREMENTS AS A METHOD TO ESTIMATE BODY-WATER COMPARTMENTS [J].
LICHTENBELT, WDV ;
WESTERTERP, KR ;
WOUTERS, L ;
LUIJENDIJK, SCM .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (02) :159-166
[8]
Analytic assessment of the various bioimpedance methods used to estimate body water [J].
Matthie, J ;
Zarowitz, B ;
De Lorenzo, A ;
Andreoli, A ;
Katzarski, K ;
Pan, G ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (05) :1801-1816
[9]
Bioimpedance spectrometry in the determination of body water compartments: Accuracy and clinical significance [J].
Thomas, BJ ;
Ward, LC ;
Cornish, BH .
APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) :447-455
[10]
FLUID CHANGES DURING PREGNANCY - USE OF BIOIMPEDANCE SPECTROSCOPY [J].
VANLOAN, MD ;
KOPP, LE ;
KING, JC ;
WONG, WW ;
MAYCLIN, PL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (03) :1037-1042