Enzymatic Microreactor Using Si, Glass and EPON SU-8

被引:9
作者
Strike, D. J. [1 ]
Fiaccabrino, G. -C. [1 ]
Koudelka-Hep, M. [1 ]
de Rooij, N. F. [1 ]
机构
[1] Univ Neuchatel, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
microreactor; microfluidics; EPON SU-8; glucose; control pore glass;
D O I
10.1023/A:1009972210811
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article describes the design, fabrication and initial testing of an enzymatic microreactor using Si, glass, epoxy and Perspex components. The microreactor geometry was defined by a photostructured EPON SU-8 spacer. This gave two chambers, an upstream chamber (vol. similar to 2.7 mu l) which was packed with control pore glass (CPG) and a downstream chamber (vol. similar to 1.5 mu l) which contained the detectors. Eleven EPON SU-8 columns separated the chambers and prevented the CPG from passing. Glucose detection via glucose oxidase immobilized to the CPG was used as a model system. Conversion efficiencies between 15 and 60% at flow rates of 150 and 26 mu 1 min(-1) respectively were obtained. Overall the system was found to be robust and to have a lifetime of at least one month.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 15 条
[1]  
Cabral J.M.S., 1991, PROTEIN IMMOBILIZATI
[2]   Porous silicon as the carrier matrix in microstructured enzyme reactors yielding high enzyme activities [J].
Drott, J ;
Lindstrom, K ;
Rosengren, L ;
Laurell, T .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (01) :14-23
[3]  
Fiaccabrino GC, 1998, ELECTROANAL, V10, P217, DOI 10.1002/(SICI)1521-4109(199804)10:4<217::AID-ELAN217>3.0.CO
[4]  
2-W
[5]   SILICON-WAFER INTEGRATED ENZYME REACTORS [J].
LAURELL, T ;
DROTT, J ;
ROSENGREN, L .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :289-299
[6]   A MICROMACHINED ENZYME REACTOR IN (110)-ORIENTED SILICON [J].
LAURELL, T ;
ROSENGREN, L .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) :614-617
[7]   Micromachining applications of a high resolution ultrathick photoresist [J].
Lee, KY ;
LaBianca, N ;
Rishton, SA ;
Zolgharnain, S ;
Gelorme, JD ;
Shaw, J ;
Chang, THP .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1995, 13 (06) :3012-3016
[8]   SU-8: a low-cost negative resist for MEMS [J].
Lorenz, H ;
Despont, M ;
Fahrni, N ;
LaBianca, N ;
Renaud, P ;
Vettiger, P .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) :121-124
[9]   INTEGRATION OF ENZYME-IMMOBILIZED COLUMN WITH ELECTROCHEMICAL FLOW CELL USING MICROMACHINING TECHNIQUES FOR A GLUCOSE DETECTION SYSTEM [J].
MURAKAMI, Y ;
TAKEUCHI, T ;
YOKOYAMA, K ;
TAMIYA, E ;
KARUBE, I ;
SUDA, M .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2731-2735
[10]  
Renaud P, 1998, MICROTOTAL ANAL SYST, P17