Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen

被引:68
作者
Hirokawa, Yuusuke [1 ]
Isoda, Hiroyoshi [1 ]
Maetani, Yoji S. [1 ]
Arizono, Shigeki [1 ]
Shimada, Kotaro [1 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Diagnost Radiol, Sakyo Ku, Kyoto 6068507, Japan
关键词
PROPELLER (BLADE); parallel imaging acquisition; upper abdomen; echo train length (ETL); blade width; k-space coverage;
D O I
10.1002/jmri.21538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate motion correction effect and image quality in the upper abdomen with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique. Materials and Methods. A total of 50 consecutive patients underwent abdominal MR imaging. Fat-saturated T2-weighted turbo spin-echo sequences were obtained by respiratory triggering. The subjects were examined with three different conditions of echo train length (ETL), blade width, and percent k-space coverage in the same scanning time: 19/30/100%, 30/30/100%, and 30/52/175%, which were designated as L/C(1), L/C(2), and L/C(3), respectively. The parallel imaging acquisition technique was used to either reduce ETL from 30 to 19 in L/C(1) or increase k-space coverage from 100% to 175% in L/C(3) compared with L/C(2). Motion and streak artifacts, and overall image quality were evaluated visually by two radiologists, independently. Results: Motion and streak artifacts were mostly reduced in L/C(3) condition. The L/C(3) image also gave the best overall image quality compared with other conditions (P < 0.001). The inter-rater reliability for each evaluation agreed well. Conclusion: In upper abdominal BLADE MRI, it was possible to reduce image artifacts and obtain better image quality by increasing the k-space coverage with parallel imaging in the same scanning time.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 26 条
[1]   k-space undersampling in PROPELLER imaging [J].
Arfanakis, K ;
Tamhane, AA ;
Pipe, JG ;
Anastasio, MA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :675-683
[2]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[3]   MR ARTIFACTS - A REVIEW [J].
BELLON, EM ;
HAACKE, EM ;
COLEMAN, PE ;
SACCO, DC ;
STEIGER, DA ;
GANGAROSA, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1271-1281
[4]   Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen [J].
Deng, Jie ;
Miller, Frank H. ;
Salem, Riad ;
Omary, Reed A. ;
Larson, Andrew C. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (10) :769-775
[5]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[6]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[7]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[8]  
FOBES KP, 2002, RADIOLOGY, V225, P551
[9]  
FOBES KP, 2003, AM J NEURORADIOL, V24, P794
[10]   PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion [J].
Forbes, KPN ;
Pipe, JG ;
Bird, CR ;
Heiserman, JE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :215-222