Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen

被引:85
作者
Deng, Jie
Miller, Frank H.
Salem, Riad
Omary, Reed A.
Larson, Andrew C.
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
diffusion-weighted imaging; multishot; PROPELLER; BLADE; abdomen;
D O I
10.1097/01.rli.0000236808.84746.95
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to evaluate the feasibility of using multishot PROPELLER for diffusion-weighted imaging (DWI) of the abdomen. Materials and Methods: Diffusion-weighted abdominal imaging was performed in 9 healthy volunteers and 3 patients using both single-shot DW-SE-EPI and multishot DW-PROPELLER (BLADE sequence). We compared ADC measurements in phantoms, liver and pancreatic tissues and performed qualitative comparisons of the diffusion-weighted images and ADC maps provided by these 2 techniques. Results: DW-PROPELLER significantly improved image quality (P < 0.05) with reduced geometric distortion and artifact. The ADC values of phantoms and abdominal organs measured by DW-PROPELLER were generally greater than those measured by single-shot DW-SE-EPI. The ADC values measured by both DWI techniques were significantly different for liver tissues but not for pancreatic tissues (P < 0.05). Preliminary patient studies demonstrated clearly distinguished lesion areas from surrounding normal liver tissues in the DW-PROPELLER images. DW-PROPELLER offers the potential for high-resolution DWI of the abdomen. Conclusions: The multishot DW-PROPELLER sequence is a promising technique for DWI of abdominal organs. Future clinical studies will evaluate the use of DW-PROPELLER technique for abdominal oncologic imaging applications.
引用
收藏
页码:769 / 775
页数:7
相关论文
共 38 条
  • [1] Periodically rotated overlapping parallel lines with enhanced reconstruction-based diffusion tensor imaging - Comparison with echo planar imoging-based diffusion tensor imaging
    Abe, O
    Mori, H
    Aoki, S
    Kunimatsu, A
    Hayashi, N
    Masumoto, T
    Yamada, H
    Masutani, Y
    Kabasawa, H
    Ohtomo, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (05) : 654 - 660
  • [2] Diffusion tensor imaging using single-shot SENSE-EPI
    Bammer, R
    Auer, M
    Keeling, SL
    Augustin, M
    Stables, LA
    Prokesch, RW
    Stollberger, R
    Moseley, ME
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 128 - 136
  • [3] Bruning R, 1996, INVEST RADIOL, V31, P709
  • [4] Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    Butts, K
    deCrespigny, A
    Pauly, JM
    Moseley, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 763 - 770
  • [5] AUTOMATED MEASUREMENT OF SELF-DIFFUSION COEFFICIENTS BY SPIN-ECHO METHOD
    CANTOR, DM
    JONAS, J
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1977, 28 (02) : 157 - 162
  • [6] Diffusion-weighted MR imaging of the liver: distinguishing hepatic abscess from cystic or necrotic tumor
    Chan, JHM
    Tsui, EYK
    Luk, SH
    Fung, ASL
    Yuen, MK
    Szeto, ML
    Cheung, YK
    Wong, KPC
    [J]. ABDOMINAL IMAGING, 2001, 26 (02): : 161 - 165
  • [7] Superparamagnetic iron oxide-enhanced liver magnetic resonance imaging - Comparison of 1.5 T and 3.0 T imaging for detection of focal malignant liver lesions
    Chang, JM
    Lee, JM
    Lee, MW
    Choi, JY
    Kim, SH
    Lee, JY
    Han, JK
    Choi, BI
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 168 - 174
  • [8] Single breath-hold diffusion-weighted imaging of the abdomen
    Chow, LC
    Bammer, R
    Moseley, ME
    Sommer, FG
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) : 377 - 382
  • [9] In vivo diffusion-weighted imaging of liver tumor necrosis in the VX2 rabbit model at 1.5 Tesla
    Deng, J
    Rhee, TK
    Sato, KT
    Salem, R
    Haines, K
    Paunesku, T
    Mulcahy, MF
    Miller, FH
    Omary, RA
    Larson, AC
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (04) : 410 - 414
  • [10] Diffusion-weighted MR imaging for determination of hepatocellular carcinoma response to yttrium-90 radioembolization
    Deng, Jie
    Miller, Frank H.
    Rhee, Thomas K.
    Sato, Kent T.
    Mulcahy, Mary F.
    Kulik, Laura M.
    Salem, Riad
    Omary, Reed A.
    Larson, Andrew C.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (07) : 1195 - 1200