Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes

被引:189
作者
Butts, K [1 ]
deCrespigny, A [1 ]
Pauly, JM [1 ]
Moseley, M [1 ]
机构
[1] STANFORD UNIV,DEPT ELECT ENGN,STANFORD,CA 94305
关键词
magnetic resonance imaging; echo-planar imaging; diffusion-weighted imaging; motion correction;
D O I
10.1002/mrm.1910350518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes a diffusion-weighted (DW) interleaved echo-planar imaging (IEPI) method for use on either conventional whole-body scanners or scanners equipped with highspeed gradient and receiver hardware, In combination with cardiac gating and motion correction with a pair of orthogonal navigator echoes, the presented method is time-efficient, compensates for patient motions, and is less sensitive to image distortions than single-shot methods. The motion-correction scheme consists of correction for constant and linear phase terms found from the orthogonal navigator echoes, The correction for the linear phase term in the phase-encode direction includes gridding the data to the Cartesian grid, The DW IEPI was used to image a phantom rotating about the slice-select direction, and motion correction was performed to eliminate ghost artifacts arising from motion in either the readout- or phase-encoding directions, DW IEPI with motion correction was performed on a normal volunteer and on a patient with a 26-day-old region of ischemia over much of the right hemisphere.
引用
收藏
页码:763 / 770
页数:8
相关论文
共 24 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]  
BOWTELL R, 1994, P 2 ANN M ISMRM SAN, P411
[3]  
Bracewell R., 1984, FOURIER TRANSFORM IT
[4]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[5]   NAVIGATED DIFFUSION IMAGING OF NORMAL AND ISCHEMIC HUMAN BRAIN [J].
DECRESPIGNY, AJ ;
MARKS, MP ;
ENZMANN, DR ;
MOSELEY, ME .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :720-728
[6]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[7]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[8]   FAT SUPPRESSION BY SECTION-SELECT GRADIENT REVERSAL ON SPIN-ECHO MR IMAGING - WORK IN PROGRESS [J].
GOMORI, JM ;
HOLLAND, GA ;
GROSSMAN, RI ;
GEFTER, WB ;
LENKINSKI, RE .
RADIOLOGY, 1988, 168 (02) :493-495
[9]   FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING [J].
IRARRAZABAL, P ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :656-662
[10]   SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING [J].
JACKSON, JI ;
MEYER, CH ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :473-478