Blood loss after total knee replacement - Effects of computer-assisted surgery

被引:172
作者
Kalairajah, Y [1 ]
Simpson, D [1 ]
Cossey, AJ [1 ]
Verrall, GM [1 ]
Spriggins, AJ [1 ]
机构
[1] Sportsmed SA, Adelaide, SA 5069, Australia
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2005年 / 87B卷 / 11期
关键词
D O I
10.1302/0301-620X.87B11.16474
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We carried out a prospective randomised study to evaluate the blood loss in 60 patients having a total knee arthroplasty and divided randomly into two equal groups, one having a computer-assisted procedure and the other a standard operation. The surgery was carried out by a single surgeon at one institution using a uniform approach. The only variable in the groups was the use of intramedullary femoral and tibial alignment jigs in the standard group and single tracker pins of the imageless navigation system in the tibia and femur in the navigated group. The mean drainage of blood was 1351 ml (715 to 2890; 95% confidence interval (CV 1183 to 1518) in the computer-aided group and 1747 ml (1100 to 3030; Cl 1581 to 1912) in the conventional group. This difference was statistically significant (p = 0.001). The mean calculated loss of haemoglobin was 36 g/dl in the navigated group versus 53 g/dl in the conventional group; this was significant at p < 0.00001. There was a highly significant reduction in blood drainage and the calculated Hb loss between the computer-assisted and the conventional techniques. This allows the ordering of less blood before the operation, reduces risks at transfusion and gives financial saving. Computer-assisted surgery may also be useful for patients in whom blood products are not acceptable.
引用
收藏
页码:1480 / 1482
页数:3
相关论文
共 18 条
[1]   An analysis of blood management in patients having a total hip or knee arthroplasty [J].
Bierbaum, BE ;
Callaghan, JJ ;
Galante, JO ;
Rubash, HE ;
Tooms, RE ;
Welch, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :2-10
[2]   A standardized method for calculating blood loss [J].
Brecher, ME ;
Monk, T ;
Goodnough, LT .
TRANSFUSION, 1997, 37 (10) :1070-1074
[3]   Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis [J].
Charrois, O ;
Kahwaji, A ;
Vastel, L ;
Rosencher, N ;
Courpied, JP .
INTERNATIONAL ORTHOPAEDICS, 2001, 25 (01) :22-24
[4]   Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol) [J].
Chauhan, SK ;
Clark, GW ;
Lloyd, S ;
Scott, RG ;
Breidahl, W ;
Sikorski, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :818-823
[5]   Transfusion options in total joint arthroplasty [J].
Keating, EM ;
Ritter, MA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :125-128
[6]   Sealing the intramedullary femoral canal with autologous bone plug in total knee arthroplasty [J].
Ko, PS ;
Tio, MK ;
Tang, YK ;
Tsang, WL ;
Lam, JJ .
JOURNAL OF ARTHROPLASTY, 2003, 18 (01) :6-9
[7]   Current concepts review blood transfusion in orthopaedic operations [J].
Lemos, MJ ;
Healy, WL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08) :1260-1270
[8]   The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty - A prospective, randomized, multicenter study [J].
Levy, O ;
Martinowitz, U ;
Oran, A ;
Tauber, C ;
Horoszowski, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (11) :1580-1588
[9]   BLOOD-LOSS AFTER TOTAL KNEE REPLACEMENT - EFFECTS OF TOURNIQUET RELEASE AND CONTINUOUS PASSIVE MOTION [J].
LOTKE, PA ;
FARALLI, VJ ;
ORENSTEIN, EM ;
ECKER, ML .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (07) :1037-1040
[10]   PERIOPERATIVE BLOOD-LOSS ASSOCIATED WITH TOTAL KNEE ARTHROPLASTY - A COMPARISON OF PROCEDURES PERFORMED WITH AND WITHOUT CEMENTING [J].
MYLOD, AG ;
FRANCE, MP ;
MUSER, DE ;
PARSONS, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07) :1010-1012