Vasovist-enhanced MR angiography

被引:44
作者
Goyen, M
Shamsi, K
Schoenberg, SO
机构
[1] Univ Med Ctr Hamburg Eppendorf, D-20246 Hamburg, Germany
[2] Berlex Labs Inc, Montville, NJ 07045 USA
[3] Univ Hosp Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
关键词
MR angiography; intravascular contrast agent; arteries; vasovist; MS-325;
D O I
10.1007/s10406-006-0162-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization.
引用
收藏
页码:B9 / B14
页数:6
相关论文
共 18 条
[1]   THE PREVALENCE OF PERIPHERAL ARTERIAL-DISEASE IN A DEFINED POPULATION [J].
CRIQUI, MH ;
FRONEK, A ;
BARRETTCONNOR, E ;
KLAUBER, MR ;
GABRIEL, S ;
GOODMAN, D .
CIRCULATION, 1985, 71 (03) :510-515
[2]   MR angiography of aortoiliac occlusive disease: A phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325 [J].
Goyen, M ;
Edelman, M ;
Perreault, P ;
O'Riordan, E ;
Bertoni, H ;
Taylor, J ;
Siragusa, D ;
Sharafuddin, M ;
Mohler, ER ;
Breger, R ;
Yucel, EK ;
Shamsi, K ;
Weisskoff, RM .
RADIOLOGY, 2005, 236 (03) :825-833
[3]  
Grist TM, 2000, JMRI-J MAGN RESON IM, V11, P32, DOI 10.1002/(SICI)1522-2586(200001)11:1<32::AID-JMRI5>3.0.CO
[4]  
2-W
[5]   Peripheral vasculature: Whole-body MR angiography with midfemoral venous compression - Initial experience [J].
Herborn, CU ;
Ajaj, W ;
Goyen, M ;
Massing, S ;
Ruehm, SG ;
Debatin, JF .
RADIOLOGY, 2004, 230 (03) :872-878
[6]   Cardiovascular screening with parallel imaging techniques and a whole-body MR imager [J].
Kramer, H ;
Schoenberg, SO ;
Nikolaou, K ;
Huber, A ;
Struwe, A ;
Winnik, E ;
Wintersperger, BJ ;
Dietrich, O ;
Kiefer, B ;
Reiser, MF .
RADIOLOGY, 2005, 236 (01) :300-310
[7]   Critical limb ischemia: Hybrid MR angiography compared with DSA [J].
Meissner, OA ;
Rieger, J ;
Weber, C ;
Siebert, U ;
Steckmeier, B ;
Reiser, MF ;
Schoenberg, SO .
RADIOLOGY, 2005, 235 (01) :308-318
[8]  
NIKOLAOU K, 2005, EUR RADIOL, P340
[9]   Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study [J].
Oudkerk, M ;
van Beek, EJR ;
Wielopolski, P ;
van Ooijen, PMA ;
Brouwers-Kuyper, EMJ ;
Bongaerts, AHH ;
Berghout, A .
LANCET, 2002, 359 (9318) :1643-1647
[10]   Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: Safety and efficacy of gadofosveset-enhanced MR angiography - Multicenter comparative phase III study [J].
Rapp, JH ;
Wolff, SD ;
Quinn, SF ;
Soto, JA ;
Meranze, SG ;
Muluk, S ;
Blebea, J ;
Johnson, SP ;
Rofsky, NM ;
Duerinckx, A ;
Foster, GS ;
Kent, KC ;
Moneta, G ;
Middlebrook, MR ;
Narra, VR ;
Toombs, BD ;
Pollak, J ;
Yucel, EK ;
Shamsi, K ;
Weisskoff, RM .
RADIOLOGY, 2005, 236 (01) :71-78