Cardiovascular screening with parallel imaging techniques and a whole-body MR imager

被引:61
作者
Kramer, H
Schoenberg, SO
Nikolaou, K
Huber, A
Struwe, A
Winnik, E
Wintersperger, BJ
Dietrich, O
Kiefer, B
Reiser, MF
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Clin Radiol, D-81377 Munich, Germany
[2] Siemens Med Solut, Erlangen, Germany
关键词
D O I
10.1148/radiol.2361040609
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to integrate parallel acquisition techniques into a comprehensive whole-body cardiovascular screening protocol to image all relevant organ systems without compromising spatial or temporal resolution. The study was approved by the institutional review board, and oral and written informed consent was obtained from each subject. Fifty subjects underwent whole-body magnetic resonance imaging that included imaging of heart, blood vessels, brain, lungs, and abdominal organs with a standard eight-channel imager. Image quality and pathologic findings were evaluated by two readers. The same protocol was then implemented with a new 32-channel whole-body imager. Depiction of 1476 (73.2%) of 2016 vessel segments was rated as good to excellent, and that of 1744 (86.5%), as without venous overlay. Interobserver agreement was good in evaluation of image quality and excellent in evaluation of pathologic findings. Acquisition time was reduced significantly (P < .05) with use of the whole-body imager and parallel acquisition techniques, which provided highquality fast cardiovascular imaging. ((c)) RSNA, 2005.
引用
收藏
页码:300 / 310
页数:11
相关论文
共 35 条
[1]   Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR Imaging [J].
Barkhausen, J ;
Goyen, M ;
Rühm, SG ;
Eggebrecht, H ;
Debatin, JF ;
Ladd, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :731-735
[2]   Sensitivity of MRI in detecting alveolar infiltrates: Experimental studies [J].
Biederer, J ;
Busse, I ;
Grimm, J ;
Reuter, M ;
Muhle, C ;
Freitag, S ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1033-1039
[3]  
Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
[4]  
2-Q
[5]   High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography [J].
Fain, SB ;
King, BF ;
Breen, JF ;
Kruger, DG ;
Riederer, SJ .
RADIOLOGY, 2001, 218 (02) :481-490
[6]   Pulmonary nodules resected at video-assisted thoracoscopic surgery: Etiology in 426 patients [J].
Ginsberg, MS ;
Griff, SK ;
Go, BD ;
Yoo, HH ;
Schwartz, LH ;
Panicek, DM .
RADIOLOGY, 1999, 213 (01) :277-282
[7]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[8]   Detection of atherosclerosis:: Systemic imaging for systemic disease with whole-body three-dimensional MR angiography -: Initial experience [J].
Goyen, M ;
Herborn, CU ;
Kröger, K ;
Lauenstein, TC ;
Debatin, JF ;
Ruehm, SG .
RADIOLOGY, 2003, 227 (01) :277-282
[9]   Whole-body three-dimensional MR angiography with a rolling table platform:: Initial clinical experience [J].
Goyen, M ;
Quick, HH ;
Debatin, JF ;
Ladd, ME ;
Barkhausen, J ;
Herborn, CU ;
Bosk, S ;
Kuehl, H ;
Schlepütz, M ;
Ruehm, SG .
RADIOLOGY, 2002, 224 (01) :270-277
[10]  
Grant Edward G, 2003, Ultrasound Q, V19, P190, DOI 10.1097/00013644-200312000-00005